Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR

Medtronic Cardiac Surgery Technologies

Minneapolis, MN

Medtronic Cardiac Surgery Technologies appears in FDA device records in Minneapolis, MN. FDA records list no 510(k) clearances, no PMA records and no registered establishments. As of , FDA records show 5 recalls for this company.

FDA records held for this company

510(k) clearances
0
PMA records
0
Recall records
5
Registered establishments
0

510(k) clearance history

No 510(k) clearance records for this company in the ingested FDA data.

No 510(k) clearance records in the ingested FDA data.

Registered establishments

No FDA establishment registrations recorded against this company.

FDA product codes

No FDA product codes recorded against this company.

Recall records

Device recall records naming this company, most recent first
RecallProductReasonClassificationInitiatedStatus
Z-1609-2008VNUS Medical U-CLIP Removal Tool, UREM1860, is intended for the removal of U-Clip anastomotic devices.Medtronic has identified one lot #0610315 of U-Clip Removal Tools, Catalog UREM1860FW, that was incorrectly assembled. The nose cone attachment, on the body of the removal tool, may not contain sufficient adhesive, which can allow the nose cone to separate from the body of the device.Terminated
Z-0727-2008Medtronic Cardioblate Gemini-s, model 49260. Surgical Ablation Device. Sterilized using Ethylene Oxide. Two, unique jaw curvatures are provided: a standard curve (model 49260) and extra curve (Model 49261). The device is intended for intermittent operation. Manufacturer: Medtronic, Inc. Minneapolis, MN 55432-5604.Mechanism failure: Medtronic has identified an issue with four lots of the Cardioblate Gemini-s Surgical Ablation Devices in which the polycarbonate distal coil retainer can fail during the course of a procedure, potentially resulting in an inability to apply the necessary jaw closure force.Terminated
Z-0968-2007Medtronic U-CLIP Anastomotic Device Removal Tool, model REM1860FW. The U-Clip Anastomotic Device Removal Tool is designed to remove U-Clip Anastomotic Devices.Six lots of U-Clip Removal Tools, catalog REM1860FW were incorrectly assembled. The nose cone attachment to the body of the removal tool does not contain sufficient adhesive which can cause the nose to separate from the body of the device.Terminated
Z-0763-06Medtronic SPYDER Anastomotic Device. Sterilized using irradiation. Do not Reuse. Nonpyrogenic. The SPYDER is designed to create an anastomosis in a rapid, automated fashion. The device creates an interrupted anastomosis without the need for aortic clamping. A specially designed aortic cutting device (ACD) (sold separately) is utilized to create the site for the anastomosis.Customers stated that the U-Clip deployment collar was either difficult to rotate or 'locks up' during usage, which prevents the deployment of the U-Clips.Terminated
Z-0351-03Medtronic Cardioblate Radio Frequency Ablation Pen, model number 60811C47The radio frequency ablation pens contained unreacted epoxy resin which was observed to leak out of the back-end of the device.Terminated

Verification record

There is no verification record for this company. Most companies on this site have none: a record exists only where a company asked to be verified and MDM ran the checks, so the absence of one says nothing about the company.

Where there is a record, this is where it appears: what was checked, when it was checked, and the current status. An MDM Verified badge on another website links to a verify address on this domain that resolves to this section. A badge that does not resolve here is not ours.

What MDM checks, and what it does not

MDM coverage

MDM coverage of this company lists here, newest first. Submit news.

Is this your company?

This page is built from public FDA records. Company pages are free and factual, and stay free whether or not anyone claims them. Membership never changes editorial coverage or vetting outcomes.

Claiming lets Medtronic Cardiac Surgery Technologies edit what it says about itself and list the categories it works in. It grants no badge: claiming is not verification.

Claim this page

Data as of , FDA export datePage updated Source: openFDA, public domain