Z-2628-2011
Servo-i Ventilator Systems; Article number 64 87 800 Intended for treatment and monitoring of patients in the...
Maquet Cardiovascular Us Sales, LLC / initiated 2011-04-20 / Terminated
Maquet Inc. began a recall of Servo-i Ventilator Systems; Article number 64 87 800 Intended for treatment and monitoring of patients in the range of neonates, infants and adults with... on . The reason FDA records is "Through customer complaints, Maquet has been informed that SERVO-i ventilators have stopped to ventilate and have generated three different technical error codes". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-2628-2011
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Maquet Cardiovascular Us Sales, LLC
- Product
- Servo-i Ventilator Systems; Article number 64 87 800 Intended for treatment and monitoring of patients in the range of neonates, infants and adults with respiratory insufficiency; these are only to be used by healthcare providers in hospitals or healthcare facilities and for in-hospital transport. These are not to be used with any anesthetic agents.
- Product code
- CBK Ventilator, Continuous, Facility Use
- Reason for recall
- Through customer complaints, Maquet has been informed that SERVO-i ventilators have stopped to ventilate and have generated three different technical error codes.
- FDA root cause
- Other
- Action
- Maquet Inc. sent an URGENT DEVICE SAFETY ALERT letter dated April 20, 2011, to all affected customers via Federal Express. The letter identified the product, the problem and the action needed to be taken by the customer. The letter informs the user of the issue and provides additional instruction and how the existing manual should be updated. Customers are asked to fill out the attached response form and fax it to 1-973-807-9210. The following warning will be included in all user's manuals delivered with new ventilators: 'Warning ! The Servo-i Ventilator System is not intended to be used during radiotherapy, since this may cause system malfunction. Warning! The Servo-s Ventilator System is not intended to be used during radiotherapy, since this may cause system malfunction.' Additionally the warning stated above will be included in the format of a sticker with the yearly preventive maintenance kit for Servo-i and SErvo-s to update exiting User's manuals for the installed base of Servo-i and SErvo-s ventilators. A maintenance report form will also be included in the kit which serves as an acknowledgement from the user that the sticker has been added to an affected ventilator unit's operating manual. For further questions, please call (973) 709-7660.
- Quantity in commerce
- 43210 units worlwide, 14412 units in the US
- Distribution
- Worldwide Distribution - USA (nationwide)
- Product codes and lots
- Article number 64 87 800; all units