Z-3084-2011
Maquet HL Console for Heart Lung Machine HL20 HL 20 4-pumps console base: P/N 917741 HL 20 5-pumps console...
Maquet Cardiovascular Us Sales, LLC / initiated 2011-06-20 / Terminated / root cause: design
Maquet Inc. began a recall of Maquet HL Console for Heart Lung Machine HL20 HL 20 4-pumps console base: P/N 917741 HL 20 5-pumps console base: P/N 917751 Intended for use as an... on . The reason FDA records is "Maquet HL 20 Twin Pump Modules may unintentionally increase speeds for a 1.5-2 second period of time before returning to its original speed". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-3084-2011
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Maquet Cardiovascular Us Sales, LLC
- Product
- Maquet HL Console for Heart Lung Machine HL20 HL 20 4-pumps console base: P/N 917741 HL 20 5-pumps console base: P/N 917751 Intended for use as an extracorporeal circulation device for perfusion lasting not more than six hours. The HL console is equipped with a rack for accommodating the system's electronic modules.
- Product code
- DTQ Console, Heart-Lung Machine, Cardiopulmonary Bypass
- Reason for recall
- Maquet HL 20 Twin Pump Modules may unintentionally increase speeds for a 1.5-2 second period of time before returning to its original speed.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Maquet sent a PRODUCT RECALL NOTIFICATION LETTER/return response forms, dated June 17, 2011, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to discontinue use of the affected product until a software update was performed by their trained technicians. Customers were also asked to forward the information contained in the notification letter to all users and to all appropriate Biomedical Staff. Customers were instructed to acknowledge receipt of the notification letter by completing and faxing back the attached response form to 973-807-9210 whether or not they have any of the affected product. For questions customers were instructed to contact their local MAQUET representative. For questions regarding this recall call 973-709-7994.
- Quantity in commerce
- 299 units
- Distribution
- Nationwide Distribution
- Product codes and lots
- 510K Number: K943803 Device Listing No.E614811 HL 20 4-umps console base: P/N 917741 HL 20 5-pumps console base: P/N 917751