Z-0168-2012
SafeSheath(R) CSG(R) Coronary Sinus guide Braided Core Hemostatic Introducer, SafeSheath(R) Worley Telescopic...
Merit Medical Systems, Inc. / initiated 2011-10-07 / Terminated / root cause: manufacturing process
Thomas Medical Products Inc began a recall of SafeSheath(R) CSG(R) Coronary Sinus guide Braided Core Hemostatic Introducer, SafeSheath(R) Worley Telescopic Braided Series, and Situs LDS2 Lead Delivery... on . The reason FDA records is "Radiopaque (RO)/soft tip of the braided core component in the CSG kits may detach from the braided core tube". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0168-2012
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Merit Medical Systems, Inc.
- Product
- SafeSheath(R) CSG(R) Coronary Sinus guide Braided Core Hemostatic Introducer, SafeSheath(R) Worley Telescopic Braided Series, and Situs LDS2 Lead Delivery System - Catalog numbers: CSG/WORLEY/BCor-1-09; CSG/WORLEY/BCor-2-09; CSG/WROLEY/L/BCor-1-09; CSG/Worley/R-1-09; CSGWORBC10M; CSGWORBC29M; CSGWORLBC19M; LVI/66-5.5-CR; LVI/66-5.5-RE; LVI/75-5-62-07-HO; LVI/75-5-62-07-HS; LVI/75-5-62-07-MP; LVI/75-5-62-07-RE; LVI/75-5-66-5.5-RE; LVI/Tele/B-60-07-HO; LVI/Tele/B-60-07-HS; LVI/Tele/B-60-07-MP; LVI/Tele/B-60-07-RE; RL065; RL066; RL067; and RL068 This device is intended to be used for the introduction of various types of pacing or defibrillator leads and catheters.
- Product code
- DYB Introducer, Catheter
- Reason for recall
- Radiopaque (RO)/soft tip of the braided core component in the CSG kits may detach from the braided core tube.
- Root cause tag
- manufacturing process
- FDA root cause
- Nonconforming Material/Component
- Action
- The firm,GE Healthcare, sent an "URGENT MEDICAL DEVICE CORRECTION" letter dated October 7, 2011, to its customers. The letter describes the product, problem and actions to be taken. The customers were instructed to immediately segregate all affected product in a manner that ensures it will not be used; return any product with reference to the return authorization (RA) number or contact customer service representative to facilitate return of product; if any affected product has been forwarded to another facility, contact that facility to arrange return, and complete and return the attached product reconciliation form. If you have any questions, you may contact the Customer Service number at 1-866-446-3003 Monday through Friday from 8:30am to 5:00pm EDT.
- Quantity in commerce
- 33,134
- Distribution
- Nationwide distribution: CA only.
- Product codes and lots
- Catalog numbers: CSG/WORLEY/BCor-1-09; CSG/WORLEY/BCor-2-09; CSG/WROLEY/L/BCor-1-09; CSG/Worley/R-1-09; CSGWORBC10M; CSGWORBC29M; CSGWORLBC19M; LVI/66-5.5-CR; LVI/66-5.5-RE; LVI/75-5-62-07-HO; LVI/75-5-62-07-HS; LVI/75-5-62-07-MP; LVI/75-5-62-07-RE; LVI/75-5-66-5.5-RE; LVI/Tele/B-60-07-HO; LVI/Tele/B-60-07-HS; LVI/Tele/B-60-07-MP; LVI/Tele/B-60-07-RE; RL065; RL066; RL067; and RL068. Lot Numbers: S24064, S24120; S24129; S24359; S24618; S24683; S24838; S24932; S25222; S25489; S25540; S25544; S25772; S25937; S25945; S26333; S26420; S26460; S36539; S36540; S26560; S36759; S36861; S26881; S26987; S27221; S27222; S27275; S27288; S27370; S27477; S27478; S27947; S27971; S27985; S28023; S28172; S28306; S28339; S28401; S28632X1; S28791; S29083; S29878; S30060X1; S30262X1; S30332X1; S30333X1; S30622X1; S30630; S30739; S30852X1; S30889X1; S30901X1; S30913; S30919X1; S30956X1; S30970; S30986X1; S30997X1; S31005X1; S31045; S31076; S31080X1; S31081; S31097; S31098; S31142X1; S31212X1; S31215X1; S31245; S31306; S31316; S31327X1; S31331X1; S31334; S31340; S31341; S31439; S31507; S31533X1; S31534X1; S31535X1; S31563; S31650; S31674; S31709; S31771X1; S31779X1; S31917X1; S31962;S32102; S32139; S32156; S32167; S32178X1; S32219; S32222; S32238; S32263; S32282; S32308; S32327; S32506X1; S32543X1; S32565X1; S32566X1; S32568X1; S32602; S32605X1; S32610; S32675; S32684; S32699X1; S32714; S32715; S32716; S32717; S32737; S32765; S32796; S32831; S32882; S32957; S32994; S33026; S33065; S33067; S33076; S33084; S33129; S33149X1; S33161X1; S33236; S33238; S33301; S33322; S33324; S33398; S33399; S33403; S33412; S33478; S33543; S33544; S33614; S33649; S33687; S33758; S33889; S33921; S33939; S34026; S34082; S34096; S34342; S34375; S34485; S34689; S34690; S36110X1; and S36118X1.