Z-0606-2012
Eius Unicompartmental Knee System Stryker Howmedica Osteonics Corp. Howmedica International S. de R.L...
Howmedica Osteonics Corp / initiated 2011-08-17 / Terminated
Stryker Howmedica Osteonics Corp. began a recall of Eius Unicompartmental Knee System Stryker Howmedica Osteonics Corp. Howmedica International S. de R.L., Raheen Business Park, Limerick, Ireland. Intended for... on . The reason FDA records is "Two National Joint Registries suggest that the EIUS Unicompartmental System is associated with a higher revision rate then the unicompartmental devices". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-0606-2012
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Howmedica Osteonics Corp
- Product
- Eius Unicompartmental Knee System Stryker Howmedica Osteonics Corp. Howmedica International S. de R.L., Raheen Business Park, Limerick, Ireland. Intended for use in Unicompartmental Knee Arthroplasty (UKA). Surgeon users have identified the following potential advantages of UKA procedures versus Total Knee Arthroplasty procedures generally: conservation of the opposite compartment, preservation of ligaments and patellofemoral articulation, reduced loss of bone stock and lower implant cost. The EIUS UKA is a Resurfacing device that requires the removal of a thin condylar cross-section intended to replace the diseased cartilage only. This allows the surgeon to conserve good quality subchondral bone.
- Product code
- NPJ Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- Two National Joint Registries suggest that the EIUS Unicompartmental System is associated with a higher revision rate then the unicompartmental devices.
- FDA root cause
- Other
- Action
- Stryker Orthopaedics sent "URGENT PRODUCT RECALL" letters dated August 17, 18 and 25, 2011 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. The letter instructs customers to complete and return an attached Product Recall Acknowledgement Form via fax to 201-831-6069. Contact the firm at 201-972-2100 for questions concerning this recall.
- Quantity in commerce
- 26,648 units
- Distribution
- Nationwide Distribution.
- Product codes and lots
- K052917, K9922887 6636-2-001 002,003, 004, 005, 011, 012, 013, 014, 015, 308, 309, 310, 312, 318, 319, 320, 322, 408, 409, 410, 412, 418, 419, 420, 422, 508, 509, 510, 512, 518, 519, 520, 522, 608, 609, 610, 612, 618, 619, 620, 622, 708, 709, 710, 712, 718, 719, 720, and 722 - ALL LOTS