Medical Device
Manufacturing
THE TRADE PAPER OF THE FACTORY FLOOR
Z-0871-2012

Presource Custom Sterile Surgical and Procedure Kits; general surgery trays; Cardinal Health, McGaw Park, IL...

Medtronic, Inc. / initiated 2011-12-12 / Terminated / root cause: manufacturing process

Cardinal Health began a recall of Presource Custom Sterile Surgical and Procedure Kits; general surgery trays; Cardinal Health, McGaw Park, IL 60085; The kit catalog numbers listed in the code... on . The reason FDA records is "Some of the components contained in the Presource kits are being recalled because Cardinal Health has determined that the component manufacturer(s) does not have all necessary FDA registrations or filings needed for...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0871-2012
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic, Inc.
Product
Presource Custom Sterile Surgical and Procedure Kits; general surgery trays; Cardinal Health, McGaw Park, IL 60085; The kit catalog numbers listed in the code information section below contain one or more of the following listed components: a) Silastic Tubing, 0.062 ID x 0.032 Wall x 50 Ft, component C-602-285, vendor part number SFM3-2850; b) Silastic Tubing, 0.040 ID x 0.023 Wall x 50 Ft, component C-SFM3-2050, vendor part number SFM3-2050; c) Pathology Container with Lid, 8 oz., component 3701Z, vendor part number 3701; d) Silicone Tubing, 0.187 ID x 0.313 OD x 50 Ft., component C-31010SG, vendor part number 31010;
Product code
LRO General Surgery Tray
Reason for recall
Some of the components contained in the Presource kits are being recalled because Cardinal Health has determined that the component manufacturer(s) does not have all necessary FDA registrations or filings needed for this product.
Root cause tag
manufacturing process
FDA root cause
PMA
Action
Cardinal Health issued an URGENT: PRODUCT RECALL letter dated December 12, 2011 to the affected hospital consignees via UPS next day air. The letter informed them that their Presource kits listed in the attached spreadsheet contain various components also listed on the attachment that are being recalled because the component manufacturer(s) do not have all the necessary FDA registrations or filings needed for these components. Enclosed with the letter were recall labels, instructing the user not to use the affected component upon opening the kit, to be affixed to the front side of each affected Presource kit and shipping carton in their inventory. The labels have an ID code which coincides with the code on the component attachment to the letter. The accounts were also requested to complete and fax back to Cardinal the enclosed reply sheet acknowledging receipt of the letter and the number of pack/modules labeled. For component credit, the consignees were instructed to contact Presource Sales Operations at 800-766-0706.
Quantity in commerce
7,213 each
Distribution
Nationwide Distribution -- California, Georgia, Illinois, Massachusetts, Michigan, New York, North Carolina, Ohio, Pennsylvania, Tennessee, Texas and Wisconsin.
Product codes and lots
all recent lots of the following kit catalog numbers PBVFLCAVJ, PCW1VPMUW, PE41TP55A, PE73EALUO, PE73MNLUM, PEDKEASTH, PEOCMEBL1, PEOCMEBLD, PEVFBHAVK, PEVFENAVH, PEVFHNAVJ, PEVNMJCHF, PG73HNLUL, PG73OTALUN, PGCGOTUI8, PGCGOTUII, PGVFGMAVM, PGVFLPAVC, PGVFMNAVG, PGVFOTAVD, PGVFTTAVK, PGVNGSCHJ, PLVFOTAVJ, PN21CYBIG, PN21CYBIH, PN41CY557, PN73CR11F, PN73SPLUT, PN73VPLUV, PNV2ALCPA, PNV2CY10Z, PNV2LM10R, PNV2OT10H, PNV2OTA10Q, PNVFLNAVK, PO73AALU1, PO73AALUR, PP69OHMLO, PUOCOT13J, PVV2CA10B, SBA13KDBSY, SBA23KTNCC, SBA23OPNCC, SBACGSTAHA, SCV11CACPR, SCV19OHCHX, SCV23MJNCH, SEN41TYCMC, SID21ACUHA, SIDCGISAUA, SNE11ALCPA, SNE11CR10F, SNE11LM10C, SNE11NMCPX, SNE14ACHHK, SNE14CRHHK, SNE14LLHHN, SNE21SHEGS, and SNE32CRSA7.