Terumo Advanced Perfusion System 1 Electronic O2 Blender/Analyzer. The electronic gas blender provides...
Terumo Cardiovascular Systems Corporation began a recall of Terumo Advanced Perfusion System 1 Electronic O2 Blender/Analyzer. The electronic gas blender provides control and monitoring of the gas flow rate and oxygen... on . FDA classified it as Class II and gives the reason as "Terumo Cardiovascular Systems (Terumo CVS) received two complaints related to the Gas System for the Terumo Advanced Perfusion System 1. Both were reported instances of users experiencing difficulty adjusting the System...". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.
Recall record
- Recall number
- Z-1962-2012
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- Terumo Advanced Perfusion System 1 Electronic O2 Blender/Analyzer. The electronic gas blender provides control and monitoring of the gas flow rate and oxygen content of the gas input to the oxygenator in the perfusion circuit. It also provides monitoring of the carbon dioxide if 95-5 (%oxygen/%carbon dioxide) is used as the blending gas.
- Product code
- DTQ Console, Heart-Lung Machine, Cardiopulmonary Bypass
- Reason for recall
- Terumo Cardiovascular Systems (Terumo CVS) received two complaints related to the Gas System for the Terumo Advanced Perfusion System 1. Both were reported instances of users experiencing difficulty adjusting the System 1 Gas System local flow control knob.
- Root cause tag
- labeling and UDI
- FDA root cause
- Error in labeling
- Action
- Terumo CVS sent an "URGENT MEDICAL DEVICE RECALL-SAFETY ADVISORY" letter dated June 22, 2012 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. Contact Terumo CVS Customer Service at 1-800-521-2818 for questions regarding this recall.
- Quantity in commerce
- 1095 Units
- Distribution
- Worldwide Distribution-USA (nationwide) and the countries of ARGENTINA, BELGIUM, CANADA, CHILE, COLOMBIA, Costa Rica, Dominican Republic, Egypt, Germany, Guatemala, Honduras, Hong Kong, India, Indonesia, Israel, Japan, Jordan, Kuwait, Malaysia, Mexico, Pakistan, Philippines, Russia, Saudi Arabia, Singapore, South Africa, South Korea, Taiwan, Thailand, Turkey, UNITED ARAB EMIRATES (UAE), and Vietnam.
- Product codes and lots
- catalog number: 801188 and Serial numbers: 0001-0006, 0008-00050, 00052-00123,00125-00152, 00154-0174,00176-00211, 00213-00241, 00245-00250, 00300-00356, 00358-00365, 00367-00449, 00451-00489, 00492-00522, 00524-00531, 00533-00649, 00651-00660, 00662-00825,0826-0830, 00831-01157, and 01160-01164.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1962-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1963-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1964-2012 | Class II | Terminated | Voluntary: Firm initiated |