LUSTER HIP SZ 3 Packaging: The product was packaged within inner and outer blister trays, sealed with coated...
DePuy Orthopaedics, Inc. began a recall of LUSTER HIP SZ 3 Packaging: The product was packaged within inner and outer blister trays, sealed with coated Tyvek lidding. The stems were packaged within... on . FDA classified it as Class II and gives the reason as "DePuy Orthopaedics, Inc. is issuing a Field Safety Notice for the LUSTER Cemented Polished Femoral Hip Stems and the ULTIMA LX Cemented Polished Femoral Hip Stems that were implanted with any metal-on-metal (MoM)...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1917-2012
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Depuy Orthopaedics Inc.
- Product
- LUSTER HIP SZ 3 Packaging: The product was packaged within inner and outer blister trays, sealed with coated Tyvek lidding. The stems were packaged within vinyl protectors, with foam taper protectors. Intended Use: The LUSTER Cemented Polished Femoral Hip Stems product are forged CoCr polished cemented stems which are used as part of a total hip arthroplasty. These stems were indicated for use with all DePuy bearings and acetabular cups.
- Product code
- JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
- Reason for recall
- DePuy Orthopaedics, Inc. is issuing a Field Safety Notice for the LUSTER Cemented Polished Femoral Hip Stems and the ULTIMA LX Cemented Polished Femoral Hip Stems that were implanted with any metal-on-metal (MoM) articulation (including a head of CoCr and an acetabular cup where the cup is of an all metal construction (monoblock or modular)).The LUSTER Cemented Polished Femoral Hip Stems and the U
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- DePuy sent an "URGENT RECALL INFORMATION-FIELD SAFETY NOTICE" letter dated May 16, 2012 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. Contact the firm at 574-372-7333 for questions regarding this notice.
- Quantity in commerce
- (85) LUSTER Cemented Polished Femoral Hip Stems in 69 lots
- Distribution
- Nationwide Distribution-including the states of CA, CO, IA, NC, OH, TX, WA, WI, and WV.
- Product codes and lots
- Product code:152180003 and Lot numbers: A46D71000, A52C11000, A88D11000, AY2CE1000, B1XGV1000, BA3BF1000, BC6BC1000, BX9B71000, Y97FM1000, and Z5NBJ1000.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1906-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1907-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1908-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1909-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1910-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1911-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1912-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1913-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1914-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1915-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1916-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1917-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1918-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1919-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1920-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1921-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1922-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1923-2012 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1924-2012 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.