Sarns Centrifugal System Control module, 220/240V The Sarns Centrifugal System is indicated for use in...
Terumo Cardiovascular Systems Corporation began a recall of Sarns Centrifugal System Control module, 220/240V The Sarns Centrifugal System is indicated for use in cardiopulmonary bypass procedures only on . FDA classified it as Class II and gives the reason as "Terumo Cardiovascular Systems (Terumo CVS) received one report of loss of power to the control module and subsequently the drive motor for the Sarns centrifugal system during cardiopulmonary bypass". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0052-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- Sarns Centrifugal System Control module, 220/240V The Sarns Centrifugal System is indicated for use in cardiopulmonary bypass procedures only.
- Product code
- KFM Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type
- Reason for recall
- Terumo Cardiovascular Systems (Terumo CVS) received one report of loss of power to the control module and subsequently the drive motor for the Sarns centrifugal system during cardiopulmonary bypass.
- Root cause tag
- design
- FDA root cause
- Component design/selection
- Action
- TERUMO sent an Urgent Medical Device Recall dated April 13, 2012, to all affected consignees. An Addendum was sent on September 25, 2012. All US Consignees will receive a Safety Advisory and an update to the Operator's Manual via Federal Express to inform them of the reported malfunction and potential hazards and to raise awareness of the benefits of using a retrograde valve and the importance of back-up system availability. TERUMO will include a customer response form and follow up with all affected users to obtain a response to the recall. For questions customers should call 1-800-521-2818. For questions regarding this recall call 734-741-6173.
- Quantity in commerce
- 213 units
- Distribution
- Worldwide Distribution - USA (nationwide) and the countries of Bangladesh, Seoul Korea, Chile, Brazil, Venesuela, Thailand, Mexico, India, Taiwan, Canada, Dominican Republic, Guatemala, Ecuador, Germany, Republic of Georgia, Hong Kong, Japan, United Arab Emirates (UAE), Japan, Belgium, Phillipines, Singapore, and South Africa.
- Product codes and lots
- Catalog number: 6380 and serial numbers: 5007, 5028-5030, 5032, 5075, 5076, 5135,6010,6013,6025,6030,6116, 7000-7197,7372, and 7373.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0051-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0052-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0053-2013 | Class II | Terminated | Voluntary: Firm initiated |