Z-1988-2012Class II

Intellispace Portal software. Intellispace Portal is a multimodality thin client applications server that...

Philips North America LLC / initiated 2012-05-23 / Terminated / root cause: software

Philips Medical Systems (Cleveland) Inc began a recall of Intellispace Portal software. Intellispace Portal is a multimodality thin client applications server that delivers full diagnostic viewing and clinical... on . FDA classified it as Class II and gives the reason as "Philips is issuing a software update to the Intellispace Portal systems to address a number of non-conformances. The most frequent and severe non-conformance identified involves the portal setting of "PAC Integration"...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-1988-2012
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Philips North America LLC
Product
Intellispace Portal software. Intellispace Portal is a multimodality thin client applications server that delivers full diagnostic viewing and clinical applications to the enterprise.
Product code
JAK System, X-Ray, Tomography, Computed
Reason for recall
Philips is issuing a software update to the Intellispace Portal systems to address a number of non-conformances. The most frequent and severe non-conformance identified involves the portal setting of "PAC Integration". This setting has a feature that allows the user to launch images of multiple patient studies into an application, but does not display a warning message informing the user that diff
Root cause tag
software
FDA root cause
Software design
Action
Philips Healthcare sent an "URGENT-MEDICAL DEVICE CORRECTION" letter dated May 23, 2012 to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. Contact your local Philips representative or the Customer Care Solutions Center at 1-800-722-9377, option 5, for questions regarding this recall.
Quantity in commerce
96
Distribution
Worldwide Distribution-USA (nationwide) including the states of AL, AZ, CA, FL, GA, IA, IN, MI, NC, NJ, NY, OK, PA, SC, TN, TX, and WA and the countries of Australia, Austria, Canada, China, Czech Republic, Denmark, and France.
Product codes and lots
Model number 881001; Serial numbers: 81172, 79937, 85083, 81097, 85145, 79916, 81132, 85011, 82020, 85007, 85006, 85081, 81028, 80914, 82004, 85041, 81180, 82016, 30019, 80910, 81133, 81098, 81169, 79940, 80980, 82036, 82007, 85084, 85085, 82039, 81127, 81165, 30003, 80818, 30007, 85042, 81184, 82021, 82030, 82023, 82051, 82026, 82024, 82028, 82050, 82025, 82029, 82027, 30018, 79933, 82015, 85089, 30036, 81183, 82037, 80425, 81157, 85025, 82011, 81174, 80965, 80966, 81026, 35006, 82009, 81013, 82003 & 80891.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1988-2012
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1988-2012Class IITerminatedVoluntary: Firm initiated