Z-2401-2012Class II
Zoll X Series Defibrillator/Pacemaker/Monitor
ZOLL Medical Corporation / initiated 2012-08-16 / Terminated / root cause: manufacturing process
ZOLL Medical Corporation began a recall of Zoll X Series Defibrillator/Pacemaker/Monitor Product Usage: The product is used by qualified medical personnel for the purpose of converting ventricular... on . FDA classified it as Class II and gives the reason as "Shipped with incorrect software". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-2401-2012
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- ZOLL Medical Corporation
- Product
- Zoll X Series Defibrillator/Pacemaker/Monitor Product Usage: The product is used by qualified medical personnel for the purpose of converting ventricular fibrillation to sinus rhythm or other cardiac rhythms capable of producing hemodynamically significant heart beats. In addition, the product may be used in synchronized mode to terminate certain atrial and ventricular tachycardias and other arrhythmias resistant to drug therapy. The X Series may be used for cardiac pacing in conscious or unconscious patients for up to a few hours duration as an alternative to endocardial stimulation. The X Series may be used for the monitoring a patients electrocardiogram (ECG).
- Product code
- MKJ Automated External Defibrillators (Non-Wearable)
- Reason for recall
- Shipped with incorrect software
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- Zoll Medical telephoned affected customers on August 16, 2012. Customers were informed of the affected product, problem and actions to be taken. Customers were instructed to remove and return the affected product for replacement. For question contact ZOLL's Technical Support.
- Quantity in commerce
- 11 units
- Distribution
- Worldwide Distribution - US Nationwide including the states of: LA, MA, ME, NC, ND, NE, OH and the country of Germany.
- Product codes and lots
- Serial Numbers: AR11J000164, AR12E000853, AR12E000856, AR12E000868, AR12E000920, AR12E000922, AR12E000923, AR12E000931, AR12E000944 AR12F001100, AR12F001298.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2401-2012 | Class II | Terminated | Voluntary: Firm initiated |