Z-2439-2012Class II

Covidien Duet TRS 60 4.8 mm Universal Articulating Single Use Loading Unit

Medtronic, Inc. / initiated 2012-08-21 / Terminated / root cause: design

Covidien LP began a recall of Covidien Duet TRS 60 4.8 mm Universal Articulating Single Use Loading Unit. Product Code: DUET6048A. Single Use Loading Unit (SULU) tissue reinforcement... on . FDA classified it as Class II and gives the reason as "Duet TRS may have the potential to injure adjacent anatomical structures which may result in life threatening post-operative complications". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-2439-2012
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic, Inc.
Product
Covidien Duet TRS 60 4.8 mm Universal Articulating Single Use Loading Unit. Product Code: DUET6048A. Single Use Loading Unit (SULU) tissue reinforcement stapler. The Endo GIA Universal Staplers with Duet TRS reloads have applications in abdominal, gynecologic and pediatric surgery for resection, transection and creation of anastomoses. They may be used for transection and resection of liver substance, hepatic vasculature and biliary structures and for transection and resection of pancreas.
Product code
GDW Staple, Implantable
Reason for recall
Duet TRS may have the potential to injure adjacent anatomical structures which may result in life threatening post-operative complications.
Root cause tag
design
FDA root cause
Device Design
Action
Covidien issued an "URGENT MEDICAL DEVICE RECALL" letter dated August 21, 2012 to all affected customers. The letter identified the product, problem, and actions to be taken by the customers. The firm sent a revised customer recall notification letter via FedEx overnight delivery to all customers who purchased Duet TRS" devices from August 2009- August 2012. This letter went to all customers whether they had been sent the August 21st letter or not. Users were advised that Covidien was recalling all lots of the Duet TRS Universal Straight and Articulating Single Use Loading Units (SULU). On August 23rd 2012, Covidien notified, via e-mail, perspective surgeons that were planning to participate in the "Duet TRS Patient Registry" of the recall and that as a result the Duet TRS registry program was discontinued. Customers were asked to complete and return a Recalled Product Form via fax to (800) 895-6140. Contact Covidien Customer Service at (800) 722-8772, option 1 for questions regarding this recall.
Quantity in commerce
135,712 units
Distribution
Worldwide Distribution.
Product codes and lots
All lot numbers

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2439-2012
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2432-2012Class IITerminatedVoluntary: Firm initiated
Z-2433-2012Class IITerminatedVoluntary: Firm initiated
Z-2434-2012Class IITerminatedVoluntary: Firm initiated
Z-2435-2012Class IITerminatedVoluntary: Firm initiated
Z-2436-2012Class IITerminatedVoluntary: Firm initiated
Z-2437-2012Class IITerminatedVoluntary: Firm initiated
Z-2438-2012Class IITerminatedVoluntary: Firm initiated
Z-2439-2012Class IITerminatedVoluntary: Firm initiated