Software for Vitrea, Vitrea fX, and Vitrea Enterprise Suite (VES): VPMC-09293C Vitrea . Model Number Vitrea...

Canon Medical Informatics, Inc. / initiated 2012-08-13 / Terminated / root cause: software

Vital Images, Inc. began a recall of Software for Vitrea, Vitrea fX, and Vitrea Enterprise Suite (VES): VPMC-09293C Vitrea . Model Number Vitrea 5.2, 6.0, 6.1, and 6.2 VPMC-09346B Vitrea fX Model... on . FDA classified it as Class II and gives the reason as "Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.

Recall record

Recall number
Z-0186-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Canon Medical Informatics, Inc.
Product
Software for Vitrea, Vitrea fX, and Vitrea Enterprise Suite (VES): VPMC-09293C Vitrea . Model Number Vitrea 5.2, 6.0, 6.1, and 6.2 VPMC-09346B Vitrea fX Model Number Vitrea fX 3.1, 5.2, 6.0, 6.1, and 6.2 VPMC-11731A Vitrea Enterprise Suite Model Number Vitrea Enterprise Suite 1.3, 6.0, 6.1, and 6.2. The software is a medical diagnostic system that allows the processing, review, analysis, communication, and media interchange of multi-dimensional digital images acquired from a variety of imaging devices. It provides the ability to review digital images from original DICOM data for multiple modalities, including CT, MR, DR, CR, XA, US, NM, PET, etc. The software is not meant for primary image interpretation in mammography. The Vitrea VScore option is intended for cardiac scoring from whole body CT derived measurements, including non-invasive detection and quantification of atherosclerotic plaque. Two image processing options, EKG Gate and Auto Gate, allow the operator to select images with reduced motion artifacts when processing data for Coronary Artery Calcification Scoring.
Product code
LLZ System, Image Processing, Radiological
Reason for recall
Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6.0, 6.1 and 6.2 of Vitrea and Vitrea fX; and Versions 1.3, 6.0, 6.1 and 6.2 of Vitrea Enterprise Suite; and all updates to those versions.
Root cause tag
software
FDA root cause
Software design
Action
Vital Images sent an "URGENT DEVICE CORRECTION" letter dated August 13, 2012 to all affected customers. The letter identified the product, problem, and actions to be taken by the customers. The letter gave advise on how to resolve the two issues and advised consignees to immediately inform all potential users. Contact Customer Support at 1-800-208-3005 for questions regarding the notice.
Quantity in commerce
2088 (1133 USA)
Distribution
Worldwide Distribution-USA (nationwide) including DC and Puerto Rico, and the countries of ALGERIA, ANGOLA, ARGENTINA, AUSTRALIA, AUSTRIA, BELARUS, BELGIUM, BRAZIL, BULGARIA, CANADA CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, DENMARK, ECUADOR, EGYPT, FINLAND, FRANCE, GREAT BRITAIN, GEORGIA, GERMANY, GHANA, GREECE, GUAM, HONDURAS, HONG KONG, INDIA, INDONESIA, IRAQ, IRELAND, ITALY, IVORY COAST, JAPAN, JORDAN KAZAKHSTAN, KOREA, KUWAIT, LEBANON, LITHUANIA, MALAYSIA, MEXICO, MALI, MOSCOW, MYANMAR, NAMIBIA, NETHERLANDS, NEW ZEALAND, NIGERIA, NORTHERN IRELAND, NORWAY, PAKISTAN, PANAMA, PERU, PHILIPPINES, POLAND, PORTUGAL, QATAR, ROMANIA, RUSSIA, SAUDI ARABIA, SENEGAL, SERBIA, SERBIA AND MONTENEGRO, SINGAPORE, SLOVAKIA, SLOVENIA, SOUTH AFRICA, SPAIN, SUDAN, SWEDEN, SWITZERLAND, TAIWAN, THAILAND, THE NETHERLANDS, TIBET, TURKEY, UKRAINE, UNITED KINGDOM, UZBEKISTAN, VENEZUELA, VIETNAM, AND YEMEN
Product codes and lots
Model Number Vitrea 5.2, 6.0, 6.1, and 6.2 VPMC-09346B Vitrea fX Model Number Vitrea fX 3.1, 5.2, 6.0, 6.1, and 6.2 VPMC-11731A Vitrea Enterprise Suite Model Number Vitrea Enterprise Suite 1.3, 6.0, 6.1, and 6.2.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0186-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0186-2013Class IITerminatedVoluntary: Firm initiated