STA Satellite Automated Multi-Parameter Analyzer This system is a fully automatic clinical instrument...
Diagnostica Stago, Inc. began a recall of STA Satellite Automated Multi-Parameter Analyzer This system is a fully automatic clinical instrument indicated and intended for the performance of tests on... on . FDA classified it as Class II and gives the reason as "Following a single customer complaint that incorrect INR values were occasionally printed for PT tests, even though the primary units (seconds) were correct, the firm investigated and confirmed the potential for...". As of , the recall status on record is Terminated, and MDM tags the root cause as software.
Recall record
- Recall number
- Z-0252-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Diagnostica Stago, Inc.
- Product
- STA Satellite Automated Multi-Parameter Analyzer This system is a fully automatic clinical instrument indicated and intended for the performance of tests on human plasma, the results of which aid in the diagnosis of coagulation abnormalities or in monitoring anticoagulant therapy.
- Product code
- JPA System, Multipurpose For In Vitro Coagulation Studies
- Reason for recall
- Following a single customer complaint that incorrect INR values were occasionally printed for PT tests, even though the primary units (seconds) were correct, the firm investigated and confirmed the potential for printing incorrect secondary units when using an external printer and the customer printout mode on the STA Satellite.
- Root cause tag
- software
- FDA root cause
- Software design
- Action
- Diagnostica Stago sent an Urgent Field Safety Notice dated June 12, 2012, to all affected customers via email return receipt requested on June 15, 2012. Customers were instructed to follow the instructions in the notification and complete the Customer Verification form and return to the Hotline by fax to 973-644-9348. For additional information, customers were instructed to contact the Hotline at 800-725-0607. For questions regarding this recall call 973-631-1200, ext 2044.
- Quantity in commerce
- 232 units US; 5 units Canada
- Distribution
- Worldwide Distribution - USA (nationwide) and Canada
- Product codes and lots
- K082248 D089976 Ref 58104 units
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0252-2013 | Class II | Terminated | Voluntary: Firm initiated |