Z-0173-2013Class I
V*Care Resuscitator Infant Resuscitator, VN 3000 Series, Single use, Manufactured by: Ventlab Corporation...
Salter Labs / initiated 2012-07-11 / Terminated / root cause: design
Ventlab Corporation began a recall of V*Care Resuscitator Infant Resuscitator, VN 3000 Series, Single use, Manufactured by: Ventlab Corporation, 155 Boyce Drive, Mockville, NC 27028. The Disposable... on . FDA classified it as Class I and gives the reason as "Possible volume leakage through the inlet valve during compressions of the resuscitator bag". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0173-2013
- Classification
- Class I
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Salter Labs
- Product
- V*Care Resuscitator Infant Resuscitator, VN 3000 Series, Single use, Manufactured by: Ventlab Corporation, 155 Boyce Drive, Mockville, NC 27028. The Disposable Resuscitators with optional built-in pressure monitor is intended to provide respiratory support in the presence of reversible apnea, commonly associated with cardiopulmonary arrest.
- Product code
- BTM Ventilator, Emergency, Manual (Resuscitator)
- Reason for recall
- Possible volume leakage through the inlet valve during compressions of the resuscitator bag.
- Root cause tag
- design
- FDA root cause
- Component design/selection
- Action
- VentLab Corporation sent an Attention: Recall Notification letter dated July 10, 2012, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to check their inventory for the affected product, complete and return the enclosed response form by fax to 336-753-5002, indicating whether or not their facility has any of the affected product. Customers can also scan and email the response form to [email protected]. For questions regarding this recall call 336-753-5000.
- Quantity in commerce
- 14,602 total for all units
- Distribution
- Nationwide Distribution including IL, OH, NY and TN.
- Product codes and lots
- Product List 071012, Product Codes: VN3200MB, Lot #102032, VN3100MB-2, Lot #102033; VN3100MBP, Lot #102046, 102182; VN3100MB-PW2, Lot 3102050; VN3100OB, Lot #102150.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0170-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0171-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0172-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0173-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0174-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0175-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0176-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0177-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0178-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0179-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0180-2013 | Class I | Terminated | Voluntary: Firm initiated | ||
| Z-0181-2013 | Class I | Terminated | Voluntary: Firm initiated |