Z-0513-2013Class II

DPM 6/7 Patient Monitor Manufactured in China for : Mindray DS USA, Inc. 800 MacArthur Blvd. Mahwah, NJ 07430...

Datascope Corp. / initiated 2010-08-11 / Terminated / root cause: design

Mindray DS USA, Inc. d.b.a. Mindray North America began a recall of DPM 6/7 Patient Monitor Manufactured in China for : Mindray DS USA, Inc. 800 MacArthur Blvd. Mahwah, NJ 07430 USA. Intended to be used for monitoring... on . FDA classified it as Class II and gives the reason as "There is an issue with the DPM 6 and DPM 7 monitors where the following features may be unavailable : Full Disclosure, Drug, Hemodynamic Calculations, Renal Calculations, Oxygenation Calculations, and Ventilation...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-0513-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Datascope Corp.
Product
DPM 6/7 Patient Monitor Manufactured in China for : Mindray DS USA, Inc. 800 MacArthur Blvd. Mahwah, NJ 07430 USA. Intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG (3-lead or 5-lead or 12-lead selectable). arrhythmia detection, ST Segment analysis, heart rate (HR) , respiration rate (RESP), temperature (TEMP), pulse oxygen saturation (SpO2), pulse rate (PR), non-invasive blood pressure (NIBP), invasive blood pressure (IBP), carbon dioxide (CO2), anesthetic gas (AG),impedance cardiograph (ICG), bispectral index (BIS), cardiac output (C.O.) and respiration mechanics (RM).
Product code
MHX Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Reason for recall
There is an issue with the DPM 6 and DPM 7 monitors where the following features may be unavailable : Full Disclosure, Drug, Hemodynamic Calculations, Renal Calculations, Oxygenation Calculations, and Ventilation Calculations.
Root cause tag
design
FDA root cause
Device Design
Action
Mindray sent a "PRODUCT CORRECTIVE ACTION" letter dated August 11, 2010 to all affected customers. The letter identified the product, problem, and actions to be taken by the customers. Customers should contact their Mindray Service Representative at 1-800-288-2121 for assistance with this issue.
Quantity in commerce
124 units
Distribution
Nationwide Distribution-USA (nationwide) including the states of WA, IL, FL, MN, SC, NV, MI, TN, PA, LA, NE, TX, and IA.
Product codes and lots
K092449  DPM 6- p/n 6802F-PA00001  DPM 7 - p/n 6800F-PA00001

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0513-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0513-2013Class IITerminatedVoluntary: Firm initiated