SOL SYS R 9IN CALC 2.25/21 Packaging: Product is packed within a poly protector, with protection added as...
DePuy Orthopaedics, Inc. began a recall of SOL SYS R 9IN CALC 2.25/21 Packaging: Product is packed within a poly protector, with protection added as needed for fragile points. The entire stem is then... on . FDA classified it as Class II and gives the reason as "An Engineering Analysis has determined the Solution Calcar Stem has the potential to result in impingement with a variety of heads. This impingement may not allow the stem and head to lock as intended. The amount of...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0591-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Depuy Orthopaedics Inc.
- Product
- SOL SYS R 9IN CALC 2.25/21 Packaging: Product is packed within a poly protector, with protection added as needed for fragile points. The entire stem is then placed within a foam sleeve for added protection. The assembly is then placed and sealed in an inner and outer tray for aseptic transfer. The sealed package is placed into a folding carton, labeled, and shrink wrapped. Intended Use: SOLUTION System Calcar Stems are used in total hip arthroplasty (THA) to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components.
- Product code
- LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
- Reason for recall
- An Engineering Analysis has determined the Solution Calcar Stem has the potential to result in impingement with a variety of heads. This impingement may not allow the stem and head to lock as intended. The amount of possible impingement varies depending on the femoral head. Worst case condition: Calcar stem with -2mm offset articuleze maximum of 0.937mm radial impingement. It is evident that a
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Deputh Orthopaedics sent an Urgent Information - Medical Device Recall Notice dated December , 2012, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. The notification letter instructed consignees to please cease further distribution or use of products immediately. The purpose of the communication was to inform them of this recall and request acknowledgement of receipt of this letter by their facility. Reconciliation forms should be returned to your DePuy Sales Representative or faxed to the following Fax Number: 574-371-4939. For questions regarding this recall call 574-267-8143.
- Quantity in commerce
- 1732 total all product codes
- Distribution
- Nationwide Distribution including AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, and WY and GUAYNABO, PR
- Product codes and lots
- Product Code: 157226210 and Lot codes: X43EX1000, X43EXA000, X43EY1000, X49FH1000, X4GDG1000, X57HX1000, and YH1ENA000.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0573-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0574-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0575-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0576-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0577-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0578-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0579-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0580-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0581-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0582-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0583-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0584-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0585-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0586-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0587-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0588-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0589-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0590-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0591-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0592-2013 | Class II | Terminated | Voluntary: Firm initiated |