Persona The Personalized Knee System, Natural Tibia, Cemented, 5 Degree Stemmed Tivanium Sterile This device...
Zimmer, Inc. began a recall of Persona The Personalized Knee System, Natural Tibia, Cemented, 5 Degree Stemmed Tivanium Sterile This device is indicated for patients with severe knee pain... on . FDA classified it as Class II and gives the reason as "All lots of the Persona Cemented Tibial Drill, 5 Degree Cemented Stemmed Natural Tibia implants, and associated tools including the Tibial Drill Guide, Broach, and Sizing Plate are being removed and replaced with...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0540-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- Persona The Personalized Knee System, Natural Tibia, Cemented, 5 Degree Stemmed Tivanium Sterile This device is indicated for patients with severe knee pain and disability due to: o Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. o Collagen disorders, and/or avascular necrosis of the femoral condyle. o Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. o Moderate valgus, varus, or flexion deformities.
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- All lots of the Persona Cemented Tibial Drill, 5 Degree Cemented Stemmed Natural Tibia implants, and associated tools including the Tibial Drill Guide, Broach, and Sizing Plate are being removed and replaced with enhanced products and instruments to reduce risks of tibial perforation which could result in tibial bone fracture due to the stress riser created by a perforation; tibial plate loosening
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Zimmer sent distributors beginning the week of November 14, 2012, E-mail information requesting all equipment be collected in distributors office before shipment back to Zimmer and replacement. A telephone conference discussing the recall and amended surgical technique was held the week of November 14, 2012, and Urgent Recall notices were sent to Distributors describing the devices; risks; updated surgical technique with directions to hand deliver surgeon/risk manager letters to all affected surgeons and risk managers in hospitals receiving the product. The notices included directions to remove all affected product and ensure risk manager letter is provided. The letter stated a Zimmer Inc. employee will conduct onsite reconciliation and asked return of distribution Spreadsheet to [email protected] within 24 hours of receiving notification. Product is to be returned with certificate of sterilization to Zimmer Product Service Department 1777 West Center St. Warsaw, IN 46580 or Zimmer International Logistics, Eschbach Germany for International Accounts. For questions regarding this recall call 574-372-4807.
- Quantity in commerce
- 518
- Distribution
- Worldwide Distribution - USA (nationwide) and internationally to Germany and Europe.
- Product codes and lots
- Part Number 42-5320-067-01 TIBIA SIZE D, LEFT, Lot: 62018341, 62018342, 62030572, 62030573, 62033385, 62051022, 62068416, 62076576, 62079742, 62091362, 62103717, 62103718, 62110194, 62117656, 11007593, 11007636, 11007592, 11007635, 11007594, 11007634 Part Number 42-5320-067-02 TIBIA SIZE D RIGHT, Lot: 11006514, 11007138, 11007214, 62018343, 62018344, 62033386, 62040513, 62060743, 62068417, 62076577, 62079743, 62079744, 62091363, 62103720, 62117657, 11007589, 11007590, 11007591, 11007637, 11007638, 11007639, 62140222
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0539-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0540-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0541-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0542-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0543-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0544-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0545-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0546-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0547-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0548-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0549-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0550-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0551-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0552-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0553-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0554-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0555-2013 | Class II | Terminated | Voluntary: Firm initiated |