Siemens Chek-Stix Combo Pak (Distributed OUS only) Catalog Number: 1364M Chek-Stix Positive and Negative...
Siemens Healthcare Diagnostics Inc began a recall of Siemens Chek-Stix Combo Pak (Distributed OUS only) Catalog Number: 1364M Chek-Stix Positive and Negative Control Strips for Urine Chemistry: When used with... on . FDA classified it as Class II and gives the reason as "When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F)". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0639-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Siemens Healthcare Diagnostics Inc.
- Product
- Siemens Chek-Stix Combo Pak (Distributed OUS only) Catalog Number: 1364M Chek-Stix Positive and Negative Control Strips for Urine Chemistry: When used with Siemens reagent strips and tablets for urinalysis, CHEK-STIX positive and negative control strips provide defined results for glucose, bilirubin, ketone (acetoacetic acid), specific gravity, blood, pH, protein, urobilinogin, nitrite, and leukocytes
- Product code
- JJW Urinalysis Controls (Assayed And Unassayed)
- Reason for recall
- When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F).
- Root cause tag
- manufacturing process
- FDA root cause
- Nonconforming Material/Component
- Action
- Siemens issued An Urgent Field Safety Notice via e-mail to all affected SiemensHealthcare Diagnostics Regional offices on November 21, 2012 both in the United States and foreign accounts. This notice informed customers of the issue with the CLINITEK Atlas and Chek-Stix Positive Urinalysis Control Solutions When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). You can use the reconstituted positive control solution for up to eight hours if the solution is held at 25C (77F) or lower. If the operating temperature is greater than 25C and lower than 30C (77F and 86F), the solution can be used for up to two hours. For questions regarding this recall call 781-269-3158.
- Quantity in commerce
- 325
- Distribution
- Worldwide Distribution - USA (nationwide) and internationally to Canada, Aruba, Brazil, Denmark, India, Mexico, New Zealand, Singapore,Thailand, Bahamas, South Wales, and Hong Kong,
- Product codes and lots
- Carton/Bottle Lot Number: CP0099091B P0099091B C0100101G P0100101G C0103042E P0103042E
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0635-2013 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-0636-2013 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-0637-2013 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-0638-2013 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-0639-2013 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-0640-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0641-2013 | Class III | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.
