Z-0815-2013Class II
Cloth electrodes with Carbon construction: P/N 201-1231, Cat Nos.: 201-123, 202-454, 203-118, 203-342...
NAImco Inc dba Richmar Inc / initiated 2009-11-30 / Terminated
NAImco Inc dba Richmar Inc began a recall of Cloth electrodes with Carbon construction: P/N 201-1231, Cat Nos.: 201-123, 202-454, 203-118, 203-342, 203-454, 203-493, 203-672, 400-877, and 400-877-BJC, 2"... on . FDA classified it as Class II and gives the reason as "Electrode Socket Terminal pulling away from the electrode lead wire when the electrical stim lead wire was removed". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-0815-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- NAImco Inc dba Richmar Inc
- Product
- Cloth electrodes with Carbon construction: P/N 201-1231, Cat Nos.: 201-123, 202-454, 203-118, 203-342, 203-454, 203-493, 203-672, 400-877, and 400-877-BJC, 2" x 2" Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1241, Cat Nos.: 201-124, 202-455, 203-340, 203-674, and 400-872, 2" Round Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1251, Cat Nos.: 201-138, 202-276, 202-456, 203-336, 203-680, and 400-879, 3" Round Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1381, Cat Nos.: 201-126, 203-678, and 400-856, 2" x 3.5" Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1501, Cat Nos.: 201-150 and 400-863, 1.25" Round Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1521, Cat No. 400-852, 3 x 5 Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 P/N 201-1541, Cat Nos.:201-154 and 400-865 1.5 x 2.5 Oval Electrode, Cloth, All Serial Numbers distributed between 11/01/2009 and 01/31/2010 Cutaneous electrode.
- Product code
- GXY Electrode, Cutaneous
- Reason for recall
- Electrode Socket Terminal pulling away from the electrode lead wire when the electrical stim lead wire was removed.
- FDA root cause
- Unknown/Undetermined by firm
- Action
- Rich-Mar sent "URGENT: MEDICAL DEVICE VOLUNTARY RECALL" letters to affected customers beginning on 11/30/2009. The letter identified the product, problem, and actions to be taken by the customers. Contact the firm at 423-648-7730 ext. 214 for questions relating to t his recall.
- Quantity in commerce
- 209860 electrodes
- Distribution
- Distributed in the states of GA and TN.
- Product codes and lots
- All Serial Numbers distributed between 11/01/2009 and 01/31/2010
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0815-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0816-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0817-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0818-2013 | Class II | Terminated | Voluntary: Firm initiated |