Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or...
Siemens Medical Solutions USA, Inc began a recall of Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or Luminos Select. Angiographic x-ray system on . FDA classified it as Class II and gives the reason as "Siemens has become aware of a potential malfunction and possible hazard to patients and staff when using the Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1097-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Siemens Medical Solutions USA, Inc.
- Product
- Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or Luminos Select. Angiographic x-ray system.
- Product code
- JAA System, X-Ray, Fluoroscopic, Image-Intensified
- Reason for recall
- Siemens has become aware of a potential malfunction and possible hazard to patients and staff when using the Iconos R200 C20, Iconos R200 T20, Iconos R100, Iconos MD, Iconos RHD, Luminos RF Classic, Luminos Fusion or Luminos Select. This malfunction is possible in cases where the table vertical lift movement is obstructed by a solid object which could potentially result in collision. This can re
- Root cause tag
- manufacturing process
- FDA root cause
- Process design
- Action
- Siemens sent a Customer Safety Advisory letter dated January 15th, 2013, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The SIEMENS service representative will investigate if parts need to be exchanged in your product, an if so, which parts need to be exchanged to restore the system safety and function. Please kindly confirm receipt of the Field Safety Notice by sending back the attached form. For further questions please call (610) 448-3237.
- Quantity in commerce
- 51
- Distribution
- Nationwide Distribution including the states of CA, FL, GA, IA, IN, KS, LA, ME, MI, MO, NC, NH, NJ, NY, NV, OH, PA, TN, TX, VA and WA.
- Product codes and lots
- Model Number 5902767 with serial numbers 2217, 2038, 1228, 1007, 1219, 2156, 2264, 2190, 2132, 2213, 1484, 2166, 2259, 2068, 1610, 1601, 1413, 2236, 2153, 1444, 1477, 1632, 2037, 2180, 1663, and 1612; Model Number 5902783 with serial numbers 1003, 1401, 1402, and 1405; Model Number 7152478 with serial numbers 2580, 2524, 2590, 2536, 2563, and 2534; Model Number 10093962 with serial numbers 5837, 5120, 5523, 5910, 5507, 6141, 4112, 6274, 4506, 5900, 4121, 6245, 6242, 4509, and 6113.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1097-2013 | Class II | Terminated | Voluntary: Firm initiated |