Z-2176-2013Class II
Surgical microscope The device is used to improve the visibility of objects through magnification and...
Leica Microsystems (Schweiz) AG / initiated 2012-12-18 / Terminated / root cause: design
Leica Microsystems (Schweiz) Ag began a recall of Surgical microscope The device is used to improve the visibility of objects through magnification and illumination and can be applied for observation and... on . FDA classified it as Class II and gives the reason as "The brake in the Z axis and/or brakes in the AB and C axes failed during installation". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-2176-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Leica Microsystems (Schweiz) AG
- Product
- Surgical microscope The device is used to improve the visibility of objects through magnification and illumination and can be applied for observation and documentation and for human veterinary medical treatment.
- Product code
- FSO Microscope, Surgical, General & Plastic Surgery
- Reason for recall
- The brake in the Z axis and/or brakes in the AB and C axes failed during installation.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- The firm, Leica Microsystems, sent an "URGENT MEDICAL DEVICE RECALL" letter dated December 19, 2012 to its customers. The letter described the product, problem and actions to be taken. The customers were instructed to DISCONTINUE USE until your system software is updated and to complete and return the attached Acknowledgement Form via email at [email protected] or fax to: 847-236-3747 or +41 71 726 32 49 within 10 working days after receipt of field safety notice. Your Leica Mycrosystems will contact you to make the necessary arrangements to complete an upgrade at no charge to the customers. If you have any further questions, contact Regulatory Affairs/Quality Assurance Manager at 847-405-5413 or +41 71 726 32 16.
- Quantity in commerce
- 5 units
- Distribution
- Worldwide distribution: USA (Nationwide) including states of: AK, CA, CO, NY, and OR; and countries of: Belarus, China, Hong Kong, India, Indonesia, Italy, Norway, South Africa, Spain, Sweden, Turkey, and Vietnam.
- Product codes and lots
- Serial Numbers: OH4-84712, OH4-84812, OH4-84912
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2176-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2177-2013 | Class II | Terminated | Voluntary: Firm initiated |