Z-1272-2013Class II

Siemens Healthcare Diagnostics Inc. MIcroScan MICroSTREP plus Type 1 B1027-201 panels. .MICroSTREP panels are...

Siemens Healthcare Diagnostics Inc. / initiated 2013-03-06 / Terminated

Siemens Healthcare Diagnostics, Inc. began a recall of Siemens Healthcare Diagnostics Inc. MIcroScan MICroSTREP plus Type 1 B1027-201 panels. .MICroSTREP panels are designed for use in determining antimicrobial... on . FDA classified it as Class II and gives the reason as "Customer complaint investigation confirmed the issue of false skipped wells and false susceptible misreads with A. agalactiae affecting multiple antimicrobial agents on MicroScan Microbiology Systems". As of , the recall status on record is Terminated.

Recall record

Recall number
Z-1272-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Siemens Healthcare Diagnostics Inc.
Product
Siemens Healthcare Diagnostics Inc. MIcroScan MICroSTREP plus Type 1 B1027-201 panels. .MICroSTREP panels are designed for use in determining antimicrobial agent susceptibility of aerobic nonenterococcal streptococci (including Streptococcus pneumoniae) and Haemophilus spp.
Product code
LTT Panels, Test, Susceptibility, Antimicrobial
Reason for recall
Customer complaint investigation confirmed the issue of false skipped wells and false susceptible misreads with A. agalactiae affecting multiple antimicrobial agents on MicroScan Microbiology Systems.
FDA root cause
Under Investigation by firm
Action
Siemens Healthcare sent a Urgent Field Safety Notification letter dated March 6, 2013, to all affected customers of MicroScan MICroSTREP plus type 1, who process panels in a Walk Away System. The letter identified the product the problem and the action needed to be taken by the customer. As stated in our product Instructions for Use, test results should be interpreted in conjunction with the patients medical history, clinical presentation and other findings. We recommend discussing the content of this letter with your laboratory director regarding the need to review previous test results, conduct patient follow-up, and/or repeat testing for testing conducted in the last twelve months. Confirmation of receipt of this letter is required. Attached you will find a form indicating you have received and understood the information. We would greatly appreciate your assistance in notifying us that you have received the information by taking a moment to complete and return the form below. If you require further information or assistance, please contact your local Siemens Healthcare Diagnostics Representative. Please forward this notification to anyone to whom you may have distributed this product. We apologize for the inconvenience that this situation has caused. For further questions please call 1-800-677-7226 Option 1 (USA/Canada) Thank you for your patience and continued support.
Quantity in commerce
21,608 boxes = 432,160 panels
Distribution
US Nationwide Distribution including Puerto Rico.
Product codes and lots
All lots within expiration: Lot numbers: 2013-02-24 2013-03-05 2013-03-06 2013-04-03 2013-04-04 2013-04-19 2013-05-01 2013-05-10 2013-05-18 2013-05-21 2013-06-07 2013-06-18 2013-06-25 2013-07-27 2013-08-10 2013-08-23 2013-09-11 2013-09-14 2013-09-28 2013-10-02 2013-11-01 2013-11-02 2013-11-15 2013-11-29 2013-12-07 2013-12-12 2013-12-17 2014-01-04 2014-01-09 2014-01-15 2014-02-01 2014-02-13.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1272-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1272-2013Class IITerminatedVoluntary: Firm initiated