Z-1405-2013Class II

AngioDynamics Micro Introducer Kits under the following labeling: 1) AngioDynamics 4F Standard...

Boston Scientific Corporation / initiated 2013-04-30 / Terminated / root cause: labeling and UDI

Angiodynamics, Inc. began a recall of AngioDynamics Micro Introducer Kits under the following labeling: 1) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597005, 2)... on . FDA classified it as Class II and gives the reason as "AngioDynamics Inc., is recalling Micro Introducer Kits and VenaCure EVLT NeverTouch Procedure Kits, because the potential exists that the micro Introducer (sheath/dilator) packaged within the kit could be the incorrect...". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-1405-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Boston Scientific Corporation
Product
AngioDynamics Micro Introducer Kits under the following labeling: 1) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597005, 2) AngioDynamics 5F Standard Micro-Introducer Kit, Sterile, Catalog number: 06597012; 3) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597013; 4) AngioDynamics 5F Standard Micro- Introducer Kit, Sterile, Catalog Number: 06597018; and 5) AngioDynamics 4F Standard Micro-Introducer Kit, Sterile, Catalog Number: 06597019. Product kits are individually wrapped in plastic, 10 units included per box. Product Usage: This device is intended to be used to measure the refractive power and the radius of corneal curvature of the human eye.
Product code
DQR Cannula, Catheter
Reason for recall
AngioDynamics Inc., is recalling Micro Introducer Kits and VenaCure EVLT NeverTouch Procedure Kits, because the potential exists that the micro Introducer (sheath/dilator) packaged within the kit could be the incorrect French size.
Root cause tag
labeling and UDI
FDA root cause
Labeling mix-ups
Action
AngioDynamics sent an Urgent Medical Device Recall letter dated April 29, 2013, to all customers by Fed Ex. The letter identified the affected product, problem and actions to be taken. Customers were instructed to lmmediately remove the affected product from inventory and call AngioDynamics, Inc. Customer Service at 1-800-772-6446 to obtain a replacement or credit for your returned product and to obtain UPS Account Number to return the package via second day delivery. Customers are instructed to segregate and return all affected devices to: AngioDynamics 603 Queensbury Avenue Queensbury, NY 12804 Attn: Micro Introducer and VenaCure EVLT NeverTouch Procedure Kits Recall Coordinator. Write the RMA number on the shipping box (Provied on the Recall Verification Tracking Form). Promptly complete, sign and return the enclosed Reply Verification Tracking Form (even if you do not have any product to return); following the directions on the notification form and the Reply Verification Form. Send the Reply Verification form to AngioDynamics either via Fax or Emai. Fax Reply Verification Tracking Form to: Attn: Micro Introducer and VenaCure EVLT NeverTouch Procedure Kits Recall Coordinatory Fax number 1-518-798-1360 or Email Reply Verification Tracking Form to: [email protected].
Quantity in commerce
Domestic(1,760 units): 1)260 units/26 boxes, 2)310 units/31 boxes,3)260 units/26 boxes,4)880 units/88 boxes,5)60 units/6 boxes,Foreign:10 units/1 box
Distribution
USA Nationwide Distribution including the states of: IL, GA, CA, NY OH, AZ, TX, NE, FL, PA, NC, WI, AL, IN, CO, MO, MT, NE, MA, VA, AK, IN, MI, NJ, MD, TN, CT, WA, MN
Product codes and lots
Corresponding Lot numbers: 1) 588918 (Expiration date 01/2016), 2) 588927 (Expiration date 12/2015), 3) 588915 (Expiration date 01/2016), 4) 588913 (Expiration date 12/2015) and 5) 588930 (Expiration date 01/2016).

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1405-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1405-2013Class IITerminatedVoluntary: Firm initiated
Z-1406-2013Class IITerminatedVoluntary: Firm initiated