Z-0858-2014Class II

Codman Certas Programmable Valve In Line Valve Only

Cerenovus, Inc. / initiated 2013-05-16 / Terminated / root cause: design

Codman & Shurtleff, Inc. began a recall of Codman Certas Programmable Valve In Line Valve Only Product Code: 82-8800 Product Usage: The CODMAN CERTAS Programmable Valve is an implantable device that... on . FDA classified it as Class II and gives the reason as "Codman Certas Programmable Valves used for hydrocephalus may not operate properly". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-0858-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Cerenovus, Inc.
Product
Codman Certas Programmable Valve In Line Valve Only Product Code: 82-8800 Product Usage: The CODMAN CERTAS Programmable Valve is an implantable device that provides constant intraventricular pressure and drainage of CSF (cerebrospinal fluid) for the management of hydrocephalus. The valve can be set to a choice of eight opening pressure settings for constant intraventricular perssure drainage of CSF. The CODMAN CERTAS Therapy Management System (TMS) allows the non-invasive reading or adjustment of the valve setting.
Product code
JXG Shunt, Central Nervous System And Components
Reason for recall
Codman Certas Programmable Valves used for hydrocephalus may not operate properly
Root cause tag
design
FDA root cause
Device Design
Action
Codman issued an Urgent Notice dated May 16, 2013, to all affected customers. The letter identifed the affected product, problem and actions to be taken. Mitigation instructions are provided and if not followed or are not successful, either issue could lead to symptoms associated with under- or over-drainage. Units not implanted are to be returned. A U.S Acknowledgement Form and fax are requested to be completed and faxed to: 1-888-943-4193, or e-mail the form to [email protected]. If you have any questions on concerns in regards to this recall, please contact your Codman Representative or Stericycle at 1-888-943-2395.
Quantity in commerce
1460 units
Distribution
Worldwide Distribution - US Nationwide, Australia, Austria, Belgium, Brazil, Switzerland, Czech Republic, Germany, Spain, Finland, France, Great Britain, Israel, Italy, Netherlands, Norway, Portugal, Russia, Saudi Arabia, Sweden, Slovenia, Slovakia, Turkey, South Africa, and UK.
Product codes and lots
Lot Codes:  CLNCB1 CMBBP1 CMBCPN CMCBWG CMCC2V CMDCN8 CMDDJN CMGB8H CMJCL8 CMJCPW CMKB21 CMMCGR CMNBFB CMNBZJ CMNC8T CMNCYL CMPB4V CNCCPF CNDBCW CNDBRH CNDCJ2 CNFCK7 CNGBG0 CNGBK2 CNHCKH CNHCZN CNJBW5 CNJBWZ CNJC38 CNJC4K CNJCD3 CNJCFR CNJCMN CNKBWP CNKCC8 CNKCL3 CNLBR6 CNLCL3 CNLCW3 CNNCWF CNPB1R CNPBRH CNPCLR CPBC96 CPBCCR CPBCRV CPCBG9 CPCCMK CPDBYC CPDC07 CPDCC7 CNBBCV CNCB6W CNGBRY CNHB95 CNNDCK CNPB1T CNPBML CPBB3G CPCBG8 CPCCBH CPCCM1 CPCCMZ CPFBKP

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0858-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0858-2014Class IITerminatedVoluntary: Firm initiated
Z-0859-2014Class IITerminatedVoluntary: Firm initiated
Z-0860-2014Class IITerminatedVoluntary: Firm initiated
Z-0861-2014Class IITerminatedVoluntary: Firm initiated
Z-0862-2014Class IITerminatedVoluntary: Firm initiated
Z-0863-2014Class IITerminatedVoluntary: Firm initiated
Z-0864-2014Class IITerminatedVoluntary: Firm initiated