REF 154215 Oxford Fixed Bearing Partial Knee Cemented Lateral Tibia Size C4 ARCOM UHMWPE / CO-CR-MO Alloy...
Biomet, Inc. began a recall of REF 154215 Oxford Fixed Bearing Partial Knee Cemented Lateral Tibia Size C4 ARCOM UHMWPE / CO-CR-MO Alloy Only for use in Lateral compartment Sterile R The... on . FDA classified it as Class II and gives the reason as "Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-1706-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- REF 154215 Oxford Fixed Bearing Partial Knee Cemented Lateral Tibia Size C4 ARCOM UHMWPE / CO-CR-MO Alloy Only for use in Lateral compartment Sterile R The Oxford Fixed Bearing Knee is a Partial knee replacement system consisting of a femoral component and a fixed bearing tibial component for use in the lateral compartment of the knee. The Oxford Fixed Lateral bearings are indicated for use in the lateral compartment and intended to be implemented with bone cement.
- Product code
- HRY Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
- Reason for recall
- Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- The firm, Biomet, sent an "URGENT MEDICAL DEVICE RECALL NOTICE" letter dated June 7, 2013 to its consignees/customers. The letter identified the device being recalled, the reason for the recall, potential adverse events associated with the recall and actions to be taken. The consignees/customers were instructed immediately locate and remove the identified device(s) listed in the letter; carefully follow the instructions on the enclosed "FAX Back Response Form"; complete and return the FAX Back Response Form to 574-372-1683 prior to return of product within three (3) business days; return Goods to Biomet, Inc 56 East Bell Drive Warsaw, IN 46580. To confirm receipt of this notice by call 574-372- 1570. Obtain an RGA # by phone (574)372-6677 email [email protected] or through FAST; use priority carrier for your shipment; and if you have further distributed this product you MUST notify personnel of the letter. Questions should be addressed to 574-372-1570 M-F 8 a.m. to 5 p.m.
- Quantity in commerce
- 30
- Distribution
- Worldwide distribution: USA including NC, IN, PA, and OH; and countries of: Canada and Netherlands.
- Product codes and lots
- M321580 , M619780, M492960, M656960, M969120 , M444790 6
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1695-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1696-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1697-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1698-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1699-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1700-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1701-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1702-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1703-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1704-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1705-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1706-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1707-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1708-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1709-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1710-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1711-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1712-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1713-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1714-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1715-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1716-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1717-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1718-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1719-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1720-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1721-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1722-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1723-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1724-2013 | Class II | Terminated | Voluntary: Firm initiated |