Z-2108-2013Class II

Axiom Artis systems. C-arm angiographic x-ray system x-ray, angiographic system

Siemens Medical Solutions USA, Inc. / initiated 2013-04-26 / Terminated / root cause: manufacturing process

Siemens Medical Solutions USA, Inc began a recall of Axiom Artis systems. C-arm angiographic x-ray system x-ray, angiographic system on . FDA classified it as Class II and gives the reason as "The firm became aware of a potential issue with Axiom Artis systems installed by a third party installer that may involve incorrect channel nuts being used". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2108-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Siemens Medical Solutions USA, Inc.
Product
Axiom Artis systems. C-arm angiographic x-ray system x-ray, angiographic system.
Product code
IZI System, X-Ray, Angiographic
Reason for recall
The firm became aware of a potential issue with Axiom Artis systems installed by a third party installer that may involve incorrect channel nuts being used.
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Siemens sent Update Instructions dated December 2012, to all affected customers. This update was initiated on behalf of the US service organization to re-check all systems installed by MEC Group. A call center representative or designated engineer called each site on April 26, 2013, and described the work being done, amount of time needed and number of engineers that would be on site. At that time the call center or engineer scheduled the update with the customer. For further questions please call (610) 219-6300.
Quantity in commerce
178
Distribution
US Distribution including the states of PA, NJ, DC, VA, MD and DE.
Product codes and lots
Multiple Model numbers: 10281163, 10281013, 10280959, 10272410, 10094200, 10094142, 10094141, 10094139, 10094137, 10094135, 10093961, 10093902, 8890415, 8890407, 8627718, 8395431, 8395415, 8395399, 8395381, 7728392, 7555373, 755365, 7555357, 7412807, 7151066, 7008605, 5904441, 5904433, 5895003, 475525, 475517, 475509.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2108-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2108-2013Class IITerminatedVoluntary: Firm initiated