Boston Scientific, Small Peripheral Cutting BalloonTM, Sterilized using irradiation: The Peripheral Cutting...
Boston Scientific Corporation began a recall of Boston Scientific, Small Peripheral Cutting BalloonTM, Sterilized using irradiation: The Peripheral Cutting Balloon Catheters are indicated for Percutaneous... on . FDA classified it as Class II and gives the reason as "Boston Scientific is initiating a recall removal of the 4.0mm x 15mm size of Small Peripheral Cutting Balloon (Monorail and Over-the-Wire) Microsurgical Dilatation Devices and Flextome Cutting Balloon (Monorail and...". As of , the recall status on record is Terminated.
Recall record
- Recall number
- Z-2137-2013
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Boston Scientific Corporation
- Product
- Boston Scientific, Small Peripheral Cutting BalloonTM, Sterilized using irradiation: The Peripheral Cutting Balloon Catheters are indicated for Percutaneous Transluminal Angioplasty (PTA) of obstructive lesions of synthetic or native arteriovenous dialysis fistulae. 1) 4.00mm x 15mm Small Peripheral Cutting BalloonTM MonorailTM Microsurgical Dilatation Device, UPN #001BPM4015140F0, Catalogue # BPM4015140F & UPN # M001PCBM4015140F0, Catalogue # PCBM4015140F. 2) 4.00mm x 15mm Small Peripheral Cutting BalloonTM Over-the-Wire Microsurgical Dilatation Device, UPN # M001PCBO4015140F0, Catalogue # PCBO4015140F.
- Product code
- LIT Catheter, Angioplasty, Peripheral, Transluminal
- Reason for recall
- Boston Scientific is initiating a recall removal of the 4.0mm x 15mm size of Small Peripheral Cutting Balloon (Monorail and Over-the-Wire) Microsurgical Dilatation Devices and Flextome Cutting Balloon (Monorail and Over-the-Wire) Microsurgical Dilation Devices. Boston Scientific has determined that users may experience significant difficulty or inability to remove the protector cap from the devic
- FDA root cause
- Process change control
- Action
- Boston Scientific sent an Urgent Medical Device Recall Removal letter dated July 30, 2013, to all affected consignees. The letter identified the product, the problem, and the action to be taken by the consignee. Consignees were advised that further distribution or use of the product should cease immediately, and to segregate the product and return it to Boston Scientific. Consignees were asked to complete and return the "Recall Removal Reply Verification Tracking Form". For questions consignees were instructed to contact their local Sales Representative. For questions regarding this recall call 763-494-2042.
- Quantity in commerce
- 1,331
- Distribution
- Worldwide Distribution - USA including AL, AZ, AR, CA, CO, CT, DE, DC, FL, GA, ID, IL, IN, IA, KY, LA, MD, MA, MI, MN, MS, MO, MT, NE, NV,NH,NJ, NY, NC, ND, OH, OK, OR, PA, RI, SC,SC, TN, TX, UT, VA, WA, WV, and WI. Internationally to Algeria, Finland, Japan, Spain, Australia, France, Latvia, Sweden, Austria, Germany, Netherlands, Switzerland, Belgium, Great Britain, Norway, Taiwan, Brazil, Greece, Panama, Turkey, Canada, Hong Kong, Poland, Unit.Arab Emir., China, India, Russian Fed., Colombia, Ireland, Saudi Arabia, Czech Republic, Israel, South Africa, Denmark, Italy, and South Korea.
- Product codes and lots
- UPN # 001BPM4015140F0, Catalogue #BPM4015140F. Lot#'s 15778169, 15735527, 15774378, 15788826, 15812347, 15824636, 15825277, 15836626, 15873338, 15891705, 15931291, 15945240, 16057260. UPN# M001PCBM4015140F0, Catalogue #PCBM4015140F, Lot #15756145. UPN # M001PCBO4015140F0, Catalogue #PCBO4015140F, Lot #'s 15688199, 15992736, 16066536, 16141255.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2137-2013 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2138-2013 | Class II | Terminated | Voluntary: Firm initiated |