Z-2250-2013Class II

ACL TOP 500 CTS; PN 0000280040 Bench top, fully automated, random access analyzer designed specifically for...

Instrumentation Laboratory Co. / initiated 2013-07-19 / Terminated / root cause: design

Instrumentation Laboratory Co. began a recall of ACL TOP 500 CTS; PN 0000280040 Bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis... on . FDA classified it as Class II and gives the reason as "Potential carryover issue that can can cause shortened APTT clotting times on the instrument". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-2250-2013
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Instrumentation Laboratory Co.
Product
ACL TOP 500 CTS; PN 0000280040 Bench top, fully automated, random access analyzer designed specifically for in vitro diagnostic clinical use in the hemostasis laboratory for coagulation and/or fibrinolysis testing in the assessment of thrombosis and/or hemostasis. The systems provide results for both direct hemostasis measurements and calculated parameters.
Product code
GKP Instrument, Coagulation, Automated
Reason for recall
Potential carryover issue that can can cause shortened APTT clotting times on the instrument.
Root cause tag
design
FDA root cause
Device Design
Action
Instrumentation Laboratory sent an Important Product Correction letter on July 19, 2013, to all affected customers. On July 23, 2013, the same communication was circulated by the IL International Group in Milan, Italy to the affected international distributors and dealers. The interim field notification was followed by the release of corrective Software V5.1.0 and Parameters P-16.3.00 (Phase II) on September 30,2013. Consignees were advised of a potential carryover issue and a workaround was provided. Consignees were asked to fax the Mandatory Response Tracking Form to 781-861-4207 or email to ra-usa.ilww.com For technical questions customers were instructed to contact the IL Technical Support Center at 1-800-678-0710, option 2. For product availability questions, customers were instructed to contact their IL Customer Service Representative at 1-800-955-9525, Option #2. For questions regarding this recall call 781-861-4467.
Quantity in commerce
2170
Distribution
Worldwide Distribution - USA including AL, AR, AZ, CA, CO, CT, DE, FL, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, and WV. Internationally to Canada, Argentina, Australia, Austria, Belarus, Belgium, Brazil, Brunei, Chile, China, Colombia, Costa Rica, Czech Republic, Denmark, Dubai, Finland, France, Germany, Great Britian, Greece, Guatemala, Hong Kong, Hungary, India, Ireland, Israel, Italy, Japan, Korea, Kuwait, Luthuania, Luxembourg, Malaysia, Mexico, Netherlands, New Zealand, Norway, Panama, Peru, Philippines, Poland, Portugal, Romania, Russia, Saudi Arabia, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, Tunisia, Turkey, Uruguay, Venezuela, and Viet Nam.
Product codes and lots
Start SN and Date: 08010100 Jan 2008 - 13072599 July 2013

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2250-2013
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2244-2013Class IITerminatedVoluntary: Firm initiated
Z-2245-2013Class IITerminatedVoluntary: Firm initiated
Z-2246-2013Class IITerminatedVoluntary: Firm initiated
Z-2247-2013Class IITerminatedVoluntary: Firm initiated
Z-2248-2013Class IITerminatedVoluntary: Firm initiated
Z-2249-2013Class IITerminatedVoluntary: Firm initiated
Z-2250-2013Class IITerminatedVoluntary: Firm initiated