Fujinon/Fujifilm Ultrasonic Endoscope Intended to provide ultrasonic images of submucosal and peripheral...

FUJIFILM Healthcare Americas Corporation / initiated 2013-07-31 / Terminated / root cause: manufacturing process

Fujinon Inc began a recall of Fujinon/Fujifilm Ultrasonic Endoscope Intended to provide ultrasonic images of submucosal and peripheral organs of the upper gastrointestinal tract for... on . FDA classified it as Class II and gives the reason as "A limited number of endoscopes were shipped to FMSU-ESD with a manufacturing defect which included missing set screws used to more securely attach the Forceps Inlet (biopsy inlet port) to the endoscope". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0112-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
FUJIFILM Healthcare Americas Corporation
Product
Fujinon/Fujifilm Ultrasonic Endoscope Intended to provide ultrasonic images of submucosal and peripheral organs of the upper gastrointestinal tract for observation, diagnosis and endoscopic treatment.
Product code
FDS Gastroscope And Accessories, Flexible/Rigid
Reason for recall
A limited number of endoscopes were shipped to FMSU-ESD with a manufacturing defect which included missing set screws used to more securely attach the Forceps Inlet (biopsy inlet port) to the endoscope.
Root cause tag
manufacturing process
FDA root cause
Unknown/Undetermined by firm
Action
The firm, FUJIFILM Medical Systems, USA, Inc. (FMSU-ESD) sent an "URGENT-MEDICAL DEVICE CORRECTION (UMDC)" and Customer Acknowledgement forms dated July 31, 2013 to their customers. The letter described the issue with the affected product; instructed customers on how to identify affected units; instructed customers to immediately cease use of the affected units; return affected units to FMSU-ESD for repairs and quality control inspection; and complete and return the attached "Customers Acknowledgement" form to FMSU-ESD, Attn: Regulatory Compliance, via fax to (973) 686-2616 or email: [email protected]. If you have any questions regarding this notice, please do not hesitate to contact Director, Quality and Regulatory Compliance, at (973) 686-2636 or by email: [email protected].
Quantity in commerce
12 Units
Distribution
Worldwide distribution: US (nationwide) including states of: NJ, PA and VA; and country of Canada.
Product codes and lots
Model Number EG-530UT2. Serial Numbers: NU038A018, NU038A019, NU038A022, NU038A027, NU038A028 and NU038A029

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0112-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0112-2014Class IITerminatedVoluntary: Firm initiated