Z-0127-2014Class II

Dekompressor Percutaneous Discectomy Probe. The Dekompressor is a single use disposable discectomy probe that...

Stryker Corp. / initiated 2013-11-04 / Terminated / root cause: design

Stryker Instruments Div. of Stryker Corporation began a recall of Dekompressor Percutaneous Discectomy Probe. The Dekompressor is a single use disposable discectomy probe that passes through and works in conjunction with an... on . FDA classified it as Class II and gives the reason as "Stryker has identified a potential for the auger and/or cannula to fracture when the Dekompressor is used contrary to the warnings in the Instructions For Use (IFU). Specifically, manually bending the cannula can weaken...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-0127-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Stryker Corp.
Product
Dekompressor Percutaneous Discectomy Probe. The Dekompressor is a single use disposable discectomy probe that passes through and works in conjunction with an introducer cannula to remove intervertebral disc nucleus pulposus material.
Product code
HRX Arthroscope
Reason for recall
Stryker has identified a potential for the auger and/or cannula to fracture when the Dekompressor is used contrary to the warnings in the Instructions For Use (IFU). Specifically, manually bending the cannula can weaken the device and may result in a fracture of the auger and/or cannula. This could result in the need for additional medical intervention to remove the broken piece, pain or loss of m
Root cause tag
design
FDA root cause
Device Design
Action
On 11/4/13, an URGENT MEDICAL DEVICE Recall Notification was sent to all domestic consignees via mail and foreign by email. An advisory was sent to every physician that uses any of the products listed. Every physician that uses any of these products must print their name and sign below which means you acknowledge that youve received a copy of the attached advisory and that you understand the information regarding the proper usage of the Decompressor. Once the form has been signed by all physicians, the form must be completed and signed by the recall coordinator. Please fax to 866-521-2762 or email to [email protected].
Quantity in commerce
20,385 total distributed since 2004
Distribution
Nationwide Distribution including the states of AR, AZ, CA, CO, FL, GA, IL, KS, MS, ND, and NE.
Product codes and lots
Part Number(s) 0407-251-000, 0407-260-000, 0407-265-000, 0407-266-000, 0407-280-000, and 0407-281-000.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0127-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0127-2014Class IITerminatedVoluntary: Firm initiated