Z-0741-2014Class II
Atrium Oasis Dry Suction Water Seal ATS (Autotransfusion) Blood Recovery System Chest Drain Dual patient lines
Atrium Medical Corporation / initiated 2013-11-19 / Terminated / root cause: design
Atrium Medical Corporation began a recall of Atrium Oasis Dry Suction Water Seal ATS (Autotransfusion) Blood Recovery System Chest Drain Dual patient lines; Product Code: 3652-100. To evacuate air and/or... on . FDA classified it as Class II and gives the reason as "Chest Drain tubing of of the ATS Blood recovery may leak or disconnect". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0741-2014
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Atrium Medical Corporation
- Product
- Atrium Oasis Dry Suction Water Seal ATS (Autotransfusion) Blood Recovery System Chest Drain Dual patient lines; Product Code: 3652-100. To evacuate air and/or fluid from the chest cavity or mediastinum.
- Product code
- CAC Apparatus, Autotransfusion
- Reason for recall
- Chest Drain tubing of of the ATS Blood recovery may leak or disconnect
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Atrium Medical issued notification letters to direct consignees by UPS next day on 19 November 2013, and indirect consignees (distributors customers) by UPS next day or USPS priority (for customers with a PO Box) on 27 November 2013. The Letter explain the issue and the steps that should be taken. The customer will be offered replacement with unaffected product or credit. The firm describes Procedures for Emergency Use. The firm identifies potential product substitutions. These products are the same drainage product without the auto-transfusion line. International Distributors. International distributors provided with the Recall Authorization' package and the customer letter. Accounts are requested to complete the Recall Reply Form acknowledging receipt of the notification. Contact Atrium Medical Customer Service at 1-800-370-7899, Monday through Friday between 9:00 am to 5:00 pm.
- Quantity in commerce
- 954 units
- Distribution
- Worldwide Distribution-USA (nationwide) and the countries of Australia, Canada, Austria, Ireland, Romania, South Africa, Colombia, Lebanon Netherlands, Jordan, Russia, and Taiwan.
- Product codes and lots
- Lot number starting with 10883097 and the ending lot number 10913346. All units in between and including these two numbers.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0735-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0736-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0737-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0738-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0739-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0740-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0741-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0742-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0743-2014 | Class II | Terminated | Voluntary: Firm initiated |