Z-0466-2014Class II

Vasoview Hemopro Endoscopic Vessel Harvesting System Maquet Cardiovascular LLC 45 Barbour Pond Drive Wayne...

Maquet Cardiovascular LLC / initiated 2013-10-30 / Terminated / root cause: design

Maquet Cardiovascular, LLC began a recall of Vasoview Hemopro Endoscopic Vessel Harvesting System Maquet Cardiovascular LLC 45 Barbour Pond Drive Wayne, NJ 07470 Indicated for use in minimally invasive... on . FDA classified it as Class II and gives the reason as "Maquet has received an increase in the number of complaints for "self-activated/remains activated/overheats" for the Hemopro VH-30000, "Hemopro 1"". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-0466-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Maquet Cardiovascular LLC
Product
Vasoview Hemopro Endoscopic Vessel Harvesting System Maquet Cardiovascular LLC 45 Barbour Pond Drive Wayne, NJ 07470 Indicated for use in minimally invasive surgery allowing access for vessel harvesting and is primarily indicated for patients undergoing endoscopic surgery for arterial bypass. It is indicated for cutting tissue and controlling bleeding through coagulation, and for patients requiring blunt dissection of tissue including dissection of blood vessels, dissection of blood vessels oft he extremities, dissection of ducts and other structures int he extraperitoneal or subcutaneous extremity and thoracic space. Extremity procedures include tissue dissection/vessel harvesting along the saphenous vein for use in coronary artery bypass grafting and peripheral artery bypass or the radial artery for use in coronary artery bypass grafting. Thorascopic procedures include exposure and dissection of structures external to the parietal pleura including nerves blood vessels and other tissues of the chest wall.
Product code
GEI Electrosurgical, Cutting & Coagulation & Accessories
Reason for recall
Maquet has received an increase in the number of complaints for "self-activated/remains activated/overheats" for the Hemopro VH-30000, "Hemopro 1"
Root cause tag
design
FDA root cause
Component design/selection
Action
Maquet Inc. sent an Urgent - Medical Device Recall (Removal) Immediate Action Required Letter dated October 30, 2013, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. Please examine your inventory immediately to determine if you have any of the affected VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System (HEMOPRO 1) VH-3000 with the lot number(s), as specified above. The VH-3000 catalog number and lot number are located on the package label. Please remove the affected VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System and place in a secure location. NOTE: VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System HEMOPRO 1 lot numbers not listed are not affected by this recall and should not be removed. HEMOPRO 2 is not affected by this recall. Your MAQUET Cardiovascular Sales Representative will contact you shortly to assist with the completion of the enclosed Acknowledgement Form (Fax Back Form), the return of any affected VASOVIEW HEMOPRO Endoscopic Vessel Harvesting System HEMOPRO 1 product and arrange for necessary replacement. We apologize for any inconvenience this may cause. If you have any questions, please contact your local MAQUET Cardiovascular Sales Representative or MAQUET Customer Service at 1-888-880-2874, Monday through Friday, between the hours of 6:00 a.m. and 5:00 p.m. PST. Thank you for your cooperation and immediate assistance.
Quantity in commerce
12,259 units
Distribution
Worldwide Distribution - USA (nationwide) and the countries of Brazil, Czech Republic, Denmark, France, Hong Kong, Italy, Middle East, Netherlands, Singapore, Switzerland, and the United Kingdom.
Product codes and lots
Catalog number VH-3000 (US) Lot numbers  25081686, 25081595, 25081460, 25081204, 25080939, 25080744, 25080418, 25080351, 25080264, 25079982, 25079913, 25073724, 25079449, 25079363, 25079086, 25078931, 25078713, 25078463, 25078291, 25078104, 25077927,25077643, 25077563, 25077123, 25076989, 25076372, 25076371, 25076133,   Catalog number  VH-3000W (Foreign) Lot numbers 25080938, 25080661, 25080311, 25078777, 25078289, 25078103 and 25077051

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0466-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0466-2014Class IITerminatedVoluntary: Firm initiated