Z-1071-2014Class I

GE Healthcare - Giraffe and Panda Bag and Mask Resuscitation System;Giraffe Stand-alone Infant Resuscitation...

GE Healthcare / initiated 2013-10-01 / Terminated / root cause: design

GE Healthcare, LLC began a recall of GE Healthcare - Giraffe and Panda Bag and Mask Resuscitation System;Giraffe Stand-alone Infant Resuscitation System. Product Usage: The Bag and Mask... on . FDA classified it as Class I and gives the reason as "Oxygen and air wall inlet fittings on the back panel of the resuscitation systems were reversed during assembly". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-1071-2014
Classification
Class I
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
GE Healthcare
Product
GE Healthcare - Giraffe and Panda Bag and Mask Resuscitation System;Giraffe Stand-alone Infant Resuscitation System. Product Usage: The Bag and Mask Resuscitation System provides the basic equipment required for pulmonary resuscitation of infants. Pulmonary resuscitation includes practices necessary to establish a clear airway and provide oxygen or air/oxygen mixtures and/or manual ventilation to the infant. These are clinical practices that represent the established standard of care.
Product code
BTM Ventilator, Emergency, Manual (Resuscitator)
Reason for recall
Oxygen and air wall inlet fittings on the back panel of the resuscitation systems were reversed during assembly.
Root cause tag
design
FDA root cause
Component design/selection
Action
GE Healthcare sent an Urgent Medical Device Correction letter dated November 18, 2013, with a return receipt to all affected customers. The letter identified the products, the problem, and safety instructions to be taken by the customer along with the product correction. It is recommended that all potential users in your facility are made aware of this safety notification and the recommended actions. Safety issues described the description and affected product details, safety instructions, photos showing the back of the resuscitation system where the Air and Oxygen fittings are located and an appendix of the Affected Product Serial Number Definition and Configurations of Fittings. For questions or concerns regarding this notification, please call the phone number listed below: United States: 1-800-345-2700.
Quantity in commerce
12, 373 units total, 8,807 = US, 3,394 = OUS, 172 = unknown
Distribution
Worldwide Distribution - USA Nationwide including the states of AK, AL, AR, AZ, CA, CO, CT, DE, FL,GA. HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and WY; and the countries of Albania, Austria, Australia, Bahrain, Belarus, Belgium, Canada, China, Costa Rica, Cyprus, Czech Republic, Denmark, Egypt, Estonia, Finland, France, Greece, Guatemala, Germany, Honduras, Hong Kong, Hungry, India, Indonesia, Ireland, Italy, Kazakhstan, Korea, Lithuania, Malaysia, Mexico, Netherlands, Norway, Peru, Poland, Romania, Russia, Saudi Arabia, South Africia, Spain, Sweden, Switzerland Turkey, United Arab, United Kingdom, and Venezuela.
Product codes and lots
QABS50026, QABR50066, QABR50068, QABR50133, QABS50023, QABR50102, QABR50103, QABR50064, QABR50065, QABR50067, QABS50070, QABS50069, QABR50275, QABS50027, QABR50274

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1071-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1070-2014Class ITerminatedVoluntary: Firm initiated
Z-1071-2014Class ITerminatedVoluntary: Firm initiated
Z-1072-2014Class ITerminatedVoluntary: Firm initiated