Z-1250-2014Class II

MOST Options" System (MOST) HINGED TIB INS SZ 1 16MM HINGED TIB INS SZ 4 6MM M HINGED TIB INS SZ 4 9MM M...

Zimmer GmbH / initiated 2014-02-25 / Terminated / root cause: packaging

Zimmer, Inc. began a recall of MOST Options" System (MOST) HINGED TIB INS SZ 1 16MM HINGED TIB INS SZ 4 6MM M HINGED TIB INS SZ 4 9MM M HINGED TIB INS SZ 4 16MM MOST PROX TIB INS 6MM on . FDA classified it as Class II and gives the reason as "A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the...". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.

Recall record

Recall number
Z-1250-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
MOST Options" System (MOST) HINGED TIB INS SZ 1 16MM HINGED TIB INS SZ 4 6MM M HINGED TIB INS SZ 4 9MM M HINGED TIB INS SZ 4 16MM MOST PROX TIB INS 6MM
Product code
KRO Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
Reason for recall
A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
Root cause tag
packaging
FDA root cause
Storage
Action
Beginning 2/25/2014 all distributors were notified via electronic mail. Hospital risk managers and distributors, surgeons with affected inventory will also be notified via courier or direct mail. The Urgent Lot Specific Recall Notice identified the issue and responsibilities. Distributors were asked to locate and remove the affected product in their territory, as well as identifying hospitals and surgeons who have previously implanted the affected product. Distributors were asked to return on-hand affected products to Zimmer and ensure all of their products are accounted for using the form provided in the letter and email it back to [email protected]. Hospital risk managers and surgeons were asked to locate affected product and return it to their Zimmer sales representative. Questions or concerns should be addressed to customer call center at 1-877-946-2761 between 8:00 am and 5:00pm EST Communications outside of the United States will occur approximately two weeks after the United States communications. 100 % effective checks will be done.
Quantity in commerce
3638 units
Distribution
Worldwide Distribution-USA (nationwide) including DC and the states of AK, AL, AR, AZ, CA, CO, CT, FL, IL, IN, KS, LA, ME, MI, MO, MS, NC, ND, NE, NJ, NY, OH, OK, OR, PA, TN, TX, UT, VA, WA, and WI, and the countries of Canada, Australia, India, Austria, Japan, Czech Republic, Seoul Korea, France, Venezuela, Germany, Luxembourg, Spain, and Switzerland.
Product codes and lots
Item Number 502001016 502004006 502004009 502004016 502010006

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1250-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1248-2014Class IITerminatedVoluntary: Firm initiated
Z-1249-2014Class IITerminatedVoluntary: Firm initiated
Z-1250-2014Class IITerminatedVoluntary: Firm initiated
Z-1251-2014Class IITerminatedVoluntary: Firm initiated
Z-1252-2014Class IITerminatedVoluntary: Firm initiated
Z-1253-2014Class IITerminatedVoluntary: Firm initiated
Z-1254-2014Class IITerminatedVoluntary: Firm initiated
Z-1255-2014Class IITerminatedVoluntary: Firm initiated
Z-1256-2014Class IITerminatedVoluntary: Firm initiated
Z-1257-2014Class IITerminatedVoluntary: Firm initiated
Z-1258-2014Class IITerminatedVoluntary: Firm initiated
Z-1259-2014Class IITerminatedVoluntary: Firm initiated
Z-1260-2014Class IITerminatedVoluntary: Firm initiated
Z-1261-2014Class IITerminatedVoluntary: Firm initiated
Z-1262-2014Class IITerminatedVoluntary: Firm initiated