Natural-Knee II Unicompartmental Knee System: UNI ALL-POLY TIB SZ 1-7mm UNI ALL-POLY TIB SZ 1-9mm
Zimmer, Inc. began a recall of Natural-Knee II Unicompartmental Knee System: UNI ALL-POLY TIB SZ 1-7mm UNI ALL-POLY TIB SZ 1-9mm on . FDA classified it as Class II and gives the reason as "A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the...". As of , the recall status on record is Terminated, and MDM tags the root cause as packaging.
Recall record
- Recall number
- Z-1252-2014
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- Natural-Knee II Unicompartmental Knee System: UNI ALL-POLY TIB SZ 1-7mm UNI ALL-POLY TIB SZ 1-9mm
- Product code
- HRY Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
- Reason for recall
- A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
- Root cause tag
- packaging
- FDA root cause
- Storage
- Action
- Beginning 2/25/2014 all distributors were notified via electronic mail. Hospital risk managers and distributors, surgeons with affected inventory will also be notified via courier or direct mail. The Urgent Lot Specific Recall Notice identified the issue and responsibilities. Distributors were asked to locate and remove the affected product in their territory, as well as identifying hospitals and surgeons who have previously implanted the affected product. Distributors were asked to return on-hand affected products to Zimmer and ensure all of their products are accounted for using the form provided in the letter and email it back to [email protected]. Hospital risk managers and surgeons were asked to locate affected product and return it to their Zimmer sales representative. Questions or concerns should be addressed to customer call center at 1-877-946-2761 between 8:00 am and 5:00pm EST Communications outside of the United States will occur approximately two weeks after the United States communications. 100 % effective checks will be done.
- Quantity in commerce
- 3638 units
- Distribution
- Worldwide Distribution-USA (nationwide) including DC and the states of AK, AL, AR, AZ, CA, CO, CT, FL, IL, IN, KS, LA, ME, MI, MO, MS, NC, ND, NE, NJ, NY, OH, OK, OR, PA, TN, TX, UT, VA, WA, and WI, and the countries of Canada, Australia, India, Austria, Japan, Czech Republic, Seoul Korea, France, Venezuela, Germany, Luxembourg, Spain, and Switzerland.
- Product codes and lots
- Item Number 613001007 613001009
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1248-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1249-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1250-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1251-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1252-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1253-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1254-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1255-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1256-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1257-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1258-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1259-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1260-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1261-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-1262-2014 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.
