Z-1244-2014Class II

Part 475630, Intramedullary Bone Saw, Cam Assembly Size 14 mm, The Biomet Intramedullary Bone Saw is a unique...

Zimmer GmbH / initiated 2014-02-26 / Terminated / root cause: labeling and UDI

Biomet, Inc. began a recall of Part 475630, Intramedullary Bone Saw, Cam Assembly Size 14 mm, The Biomet Intramedullary Bone Saw is a unique and exclusive clinical instrument that is used to... on . FDA classified it as Class II and gives the reason as "Incorrect labeling on specific lots of the Intramedullary Bone Saw. The Saw Blade Assembly was identified as CAM Assembly". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-1244-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Zimmer GmbH
Product
Part 475630, Intramedullary Bone Saw, Cam Assembly Size 14 mm, The Biomet Intramedullary Bone Saw is a unique and exclusive clinical instrument that is used to correct leg length, or rotational discrepancies in the femur.
Product code
LXH Orthopedic Manual Surgical Instrument
Reason for recall
Incorrect labeling on specific lots of the Intramedullary Bone Saw. The Saw Blade Assembly was identified as CAM Assembly.
Root cause tag
labeling and UDI
FDA root cause
Labeling False and Misleading
Action
The firm, BIOMET, sent an "URGENT MEDICAL DEVICE SAFETY ALERT" letter dated February 26, 2014 via Fed Ex overnight to domestic consignees. Australia and GSCC were notified by email and also received a hard copy letter via mail. The letter described the product, problem and actions to be taken. The letter stated that this action requires the immediate location and discontinued use of the product and its return to Biomet. The Consignees were were instructed to immediately locate, discontinue use of the product and remove the identified device(s) listed; carefully follow the instructions on the FAX Back Response Form and reply within three (3) business days; complete and return Form via Fax to: 574-372-1683 prior to return of product, and use priority carrier for your shipment. If you have further distributed this product, you MUST notify hospital personnel of this action via enclosed "Dear Risk/Recall Manager Notice", and note that you are charged with the location and return of these products. Shipping address is Return Goods, 56 E. Bell Drive Warsaw, IN 46582. Questions related to the notice should be directed to 574-372-1570, Monday through Friday, 8 a.m. to 5 p.m.
Quantity in commerce
6
Distribution
Worldwide Distribution: US (nationwide) to states of: NY, TX, MI, and M; to countries of: Australia and The Netherlands.
Product codes and lots
Lot 239470, 457450

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1244-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1242-2014Class IITerminatedVoluntary: Firm initiated
Z-1243-2014Class IITerminatedVoluntary: Firm initiated
Z-1244-2014Class IITerminatedVoluntary: Firm initiated