Sarns Malleable Dual-stage Venous Return Cannulae 28/38, 32/40 & 34/46 Fr with 1/2" connector with or without...
Terumo Cardiovascular Systems Corporation began a recall of Sarns Malleable Dual-stage Venous Return Cannulae 28/38, 32/40 & 34/46 Fr with 1/2" connector with or without Xcoating Product Usage: The Venous Return Cannula... on . FDA classified it as Class II and gives the reason as "During an in-process inspection, Terumo Cardiovascular Systems (Terumo CVS) identified the presence of loose fiber particulate that exceeded finished product specifications". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-2096-2014
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Terumo Cardiovascular Systems Corporation
- Product
- Sarns Malleable Dual-stage Venous Return Cannulae 28/38, 32/40 & 34/46 Fr with 1/2" connector with or without Xcoating Product Usage: The Venous Return Cannula is indicated for venous drainage during cardiopulmonary bypass surgery for dual cannulation of the superior and inferior vena cava.
- Product code
- DWF Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
- Reason for recall
- During an in-process inspection, Terumo Cardiovascular Systems (Terumo CVS) identified the presence of loose fiber particulate that exceeded finished product specifications
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- Terumo sent an Urgent Medical Device Recall letters dated June 27, 2014 to their customers. The letter identified the affected product, problem and actions to be taken. The letter instructed customers to 1. Review this Medical Device Recall notice, 2. Assure that all users in your institution have received notice of this issue and remove any affected units from use, 3. Fill out the Product Tracking Sheet (enclosed), indicating the number of affected units at your institution and fax to 1-877-907-7509 or email to [email protected]. 4. Complete the Packing Slip (enclosed) and follow the packing instructions to return the affected product, and 5. Terumo CVS will issue credit once the affected units are returned. For questions call Terumo CVS c/o Stericycle 1-866-629-6181.
- Quantity in commerce
- 7,190 units
- Distribution
- Worldwide Distribution - US (nationwide) in the states of: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV & WY and the countries of : Australia, Belgium, Canada, Chile, Japan, Malaysia, Mexico, Singapore, Taiwan, Thailand, United Arab Emirates (UAE) & United Kingdom.
- Product codes and lots
- Part No. 4934, Lot #: 0655207, 0657317, 0666535, 0682313, 0697852; Part No. 4934X, Lot #: 0659445, 0696672; Part No. 4935, Lot #: 0655206, 0656923, 0682315, 0685669, 0696718; Part No. 4936, Lot #: 0655292, 0665320, 0684443, 0684444, 0687492, 690459R & Part No. 4936X, Lot #: 0656438, 0661606, 683308R.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2094-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2095-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2096-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2097-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2098-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2099-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2100-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2101-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2102-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2103-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2104-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2105-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2106-2014 | Class II | Terminated | Voluntary: Firm initiated |