Z-2259-2014Class II

Medtronic, Activa PC, Model 37601, Method of Sterilization: Ethylene Oxide, Single Use Only, Rx Only. The...

Medtronic Neuromodulation / initiated 2014-07-14 / Terminated / root cause: manufacturing process

Medtronic Neuromodulation began a recall of Medtronic, Activa PC, Model 37601, Method of Sterilization: Ethylene Oxide, Single Use Only, Rx Only. The Activa PC neurostimulator is a dual-channel device... on . FDA classified it as Class II and gives the reason as "Medtronic is recalling six Activa PC (model 37601) Implantable Neurostimulators due to the potential for a damaged electrical component during manufacturing". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-2259-2014
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Medtronic Neuromodulation
Product
Medtronic, Activa PC, Model 37601, Method of Sterilization: Ethylene Oxide, Single Use Only, Rx Only. The Activa PC neurostimulator is a dual-channel device capable of delivering bilateral stimulation. Activa PC contains a non-rechargeable battery and microelectronic circuitry to deliver a controlled electrical pulse to precisely targeted areas of the brain. The device is typically implanted subcutaneously near the clavicle, connected to an extension and leads, which are implanted in the brain.
Product code
MHY Stimulator, Electrical, Implanted, For Parkinsonian Tremor
Reason for recall
Medtronic is recalling six Activa PC (model 37601) Implantable Neurostimulators due to the potential for a damaged electrical component during manufacturing.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
The firm, Medtronic, notified their Consignees on 07/14/2014 via telephone of the recall. Medtronic representative used telephone script to convey the information. The script was directed to Risk Management or Inventory Management. The caller was to inform consignees of the problem and product being recalled. Advised consignees to quarantine the product and provided the Medtronic Device Removal Reply Form to the consignees via e-mail or Fax. The Reply Form included contact information which was to call 1-800-633-8766 in case they needed to contact a Medtronic representative. The completed form is to be faxed back to 1-800-897-3899 or e-mail a PDF to [email protected]. If you have any questions, call 763-526-1294.
Quantity in commerce
6
Distribution
Distributed in the states of: MA, NC, OH, and TX.
Product codes and lots
Serial numbers: NKM724776H, NKM724782H, NKM724785H,  NKM724790H, NKM724802H, NKM724843H.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-2259-2014
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-2259-2014Class IITerminatedVoluntary: Firm initiated