PERSONA" The Personalized Knee System UC Tibial Articular Surface Provisional Left Size 3-7 CD Top; Left Size...
Zimmer, Inc. began a recall of PERSONA" The Personalized Knee System UC Tibial Articular Surface Provisional Left Size 3-7 CD Top; Left Size 4-11 EF Top; Left Size 7-12 GH Top; Left Size... on . FDA classified it as Class II and gives the reason as "Reports of breakage of the Persona Knee Trial Articular Surface Provisionals (TASPs). The Persona primary knee surgical technique has been updated. This field action correction is to ensure that all distributors and...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-2580-2014
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- PERSONA" The Personalized Knee System UC Tibial Articular Surface Provisional Left Size 3-7 CD Top; Left Size 4-11 EF Top; Left Size 7-12 GH Top; Left Size 9-12 J Top; Right Size 3-7 CD Top; Right Size 4-11 EF Top; Right Size 7-12 GH Top; and Right Size 9-12 J Top.
- Product code
- JWH Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
- Reason for recall
- Reports of breakage of the Persona Knee Trial Articular Surface Provisionals (TASPs). The Persona primary knee surgical technique has been updated. This field action correction is to ensure that all distributors and users of this instrument are aware of the enhanced surgical techniques.
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- On 8/7/2014, Zimmer notified all distributors via electronic mail. Distributors that have received affected inventory are also notified via courier. Hospital risk managers and surgeons are also notified via courier. Hospital risk managers and surgeons were provided with a notification identifying the issue and their responsibilities. These responsibilities include ensuring the affected personnel are aware of the contents of the notification. Distributors were sent a notification identifying the issue and to provide a copy of the notification sent to surgeons and risk managers. The distributors will also be instructed as needed to assist with identifying a comprehensive list of surgeons.
- Quantity in commerce
- 77,737 total units
- Distribution
- Worldwide Distribution: US (nationwide) including states of: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, WA, WI, WV, and WY; and countries of: AUSTRALIA, INDIA, JAPAN, KOREA, SINGAPORE, AUSTRIA, BELGIUM, FRANCE, GERMANY, ISRAEL, ITALY, LUXEMBOURG, NETHERLANDS, SAUDI ARABIA, SOUTH AFRICA, SPAIN, SWITZERLAND, UNITED KINGDOM, and UNITED ARAB EMIRATES.
- Product codes and lots
- Part Numbers: 42517200410, 42517200510, 42517200610, 42517200710, 42527200410, 42527200510, 42527200610, and 42527200710. Lot numbers:62034570, 62117742, 62156315, 62187322, 62247350, 62314721, 62372409, 62381836, 62397160, 62429190, 62474906, 62551390, 62565048, 62595853, 62614781, 62700416, 62702297, 62724349, 62043548, 62055681, 62104368, 62117743, 62144794, 62165545, 62177246, 62256282, 62351288, 62356244, 62391228, 62427419, 62456268, 62506003, 62551338, 62564355, 62597762, 62614786, 62702292, 62705808, 62717332, 62055682, 62068376, 62068378, 62144795, 62152727, 62187323, 62256283, 62351289, 62356275, 62386419, 62445931, 62456266, 62558584, 62575757, 62611087, 62638672, 62698749, 62736074, 62736075, 62330130, 62563854, 62567418, 62622596, 62070845, 62102088, 62130979, 62149717, 62200303, 62240485, 62256293, 62351304, 62356605, 62391239, 62420238, 62469444, 62551099, 62581081, 62597792, 62627223, 62696849, 62715617, 62059519, 62072593, 62103263, 62110051, 62196614, 62198205, 62248171, 62351307, 62385105, 62401423, 62468266, 62558588, 62595866, 62690052, 62715613, 62072225, 62103266, 62144798, 62156319, 62209049, 62229728, 62282887, 62315140, 62356622, 62386430, 62401427, 62427062, 62428459, 62505998, 62565073, 62581864, 62627283, 62690948, 62696884, 62717330, 62398030, 62428342, 62444343, 62510048, 62515508, 62516058, and 62600154.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-2575-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2576-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2577-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2578-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2579-2014 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-2580-2014 | Class II | Terminated | Voluntary: Firm initiated |