Z-0199-2015Class II

ATTUNE Intuition Distal Femoral Jig; sold non-sterile; product is wrapped in bubble wrap and then sealed...

Depuy Orthopaedics Inc. / initiated 2014-10-15 / Terminated / root cause: manufacturing process

DePuy Orthopaedics, Inc. began a recall of ATTUNE Intuition Distal Femoral Jig; sold non-sterile; product is wrapped in bubble wrap and then sealed inside a polyethylene bag on . FDA classified it as Class II and gives the reason as "Issuing a device correction because if the pin bushing is over loaded or inverted, there is the potential for partial or full displacement and fracture of the plastic around the pin bushing". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-0199-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Depuy Orthopaedics Inc.
Product
ATTUNE Intuition Distal Femoral Jig; sold non-sterile; product is wrapped in bubble wrap and then sealed inside a polyethylene bag
Product code
LXH Orthopedic Manual Surgical Instrument
Reason for recall
Issuing a device correction because if the pin bushing is over loaded or inverted, there is the potential for partial or full displacement and fracture of the plastic around the pin bushing.
Root cause tag
manufacturing process
FDA root cause
Process control
Action
DePuy sent an "URGENT DEVICE CORRECTION" notifications dated October 15, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The recall notification included a description of the reason for the recall, affected product, consignee responsibilities, and instructions for responding to the formal recall notification. For questions, please call 574-371-4917.
Quantity in commerce
3,082
Distribution
Worldwide Distribution - USA (nationwide) except AK, including Puerto Rico and the countries of Canada, Australia, Austria, Belgium, China, France, Germany, India, Ireland, Israel, Italy, Japan, Malaysia, Netherlands, New Zealand, Singapore, South Africa, South Korea, Spain, Switzerland, Thailand, UAE, United Kingdom and Chile.
Product codes and lots
Catalog NOs. 2544-00-521 and 2544-00-520; All lots are affected for the Device Correction.   Lot numbers below should be inspected and swapped out if the bushing is incorrectly assembled: Part No. DePuy Synthes Lot No: MFG Lot No: 254400520 ABC22844 C22844  ABC22845 C22845  ABC34279 C34279  ABC34280 C34280  ABC4107 C4107  ABC4108 C4108  ABC4112 C4112  ABC4113 C4113  ABC50741 C50471 254400521 ABB13662 B13662  ABB19116 B19116  ABB19117 B19117  ABB19118 B19118  ABB35392 B35392  ABB35393 B35393  ABB39835 B39835  ABB41384 B41384  ABB46872 B46872  ABB49200 B49200  ABB50724 B50724  ABB55749 B55749  ABB63598 B63598  ABB66346 B66346  ABB72107 B72107  ABB77183 B77183  ABB79390 B79390  ABB79391 B79391  ABB80712 N80712  ABC17165 C17165  ABC5023 C5023

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0199-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0199-2015Class IITerminatedVoluntary: Firm initiated