FullFire Diffusing Tip Laser Probe, REF: DTP101-01, DTP201-01, DTP301-01, DTP401-01, DTP501-01. These laser...
Monteris Medical Corp began a recall of FullFire Diffusing Tip Laser Probe, REF: DTP101-01, DTP201-01, DTP301-01, DTP401-01, DTP501-01. These laser probes are part of the NeuroBlate System, a unique... on . FDA classified it as Class II and gives the reason as "Monteris Medical received a complaint of a separation of the distal sapphire tip from the laser delivery probe". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0228-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Monteris Medical Corp
- Product
- FullFire Diffusing Tip Laser Probe, REF: DTP101-01, DTP201-01, DTP301-01, DTP401-01, DTP501-01. These laser probes are part of the NeuroBlate System, a unique collection of MRI-compatible laser devices and accessories that create an MRI guided delivery of precision thermal therapy in the brain. The NeuroBlate System components include Gas-cooled Laser Delivery Probes to deliver controlled energy to a target zone.
- Product code
- GEX Powered Laser Surgical Instrument
- Reason for recall
- Monteris Medical received a complaint of a separation of the distal sapphire tip from the laser delivery probe.
- Root cause tag
- manufacturing process
- FDA root cause
- Process control
- Action
- Monteris Medical sent an Urgent Advisory Notice of Product Recall letter dated October 3, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. Action to be taken by user: Our distribution records document that you were shipped products from the affected lots. Please check your inventory to confirm whether you have any stock affected by this notice. An acknowledgment form is included to assist you in the assessment of your inventory. Your Monteris Medical Sales Representative will be glad to assist you with this assessment. Once your inventory has been verified, please fax the form back to Monteris Medical at 763-253-4728.
- Quantity in commerce
- 133 devices
- Distribution
- US Distribution including the states of CA, CT, FL, GA, KS, MN, MO, NC, OH, PA, TX, and VA
- Product codes and lots
- serial numbers: 20414-1-C1274-03, 20414-1-C1274-04, 20414-1-C1274-06, 20414-1-C1274-07, 20414-1-C1274-08, 20414-1-C1274-09, 20414-1-C1274-11, 20414-1-C1274-12, 20414-1-C1274-13, 20414-1-C1274-17, 20414-1-C1274-19, 20414-1-C1274-20, 20414-1-C1367-01, 20414-1-C1367-02, 20414-1-C1367-04, 20414-1-C1367-05, 20414-1-C1367-06, 20414-1-C1367-07, 20414-1-C3302-02, 20414-1-C3302-05, 20414-1-C3302-08, 20414-1-C3302-10, 20414-1-C3302-12, 20414-1-C3302-13, 20414-1-C3302-14, 20414-1-C3302-15, 20414-1-C3302-16, 20414-1-C3302-17, 20414-1-C3502-01, 20414-1-C3502-02, 20414-1-C3502-03, 20414-1-C3502-05, 20414-1-C3502-06, 20414-1-C3502-07, 20414-1-C3502-08, 20414-1-C3502-09, 20414-1-C3502-10, 20414-1-C3502-11, 20414-1-C3502-12, 20414-1-C3502-13, 20414-1-C3502-14, 20414-1-C3502-15, 20414-1-C3502-16, 20414-1-C3502-17, 20414-2-C1275-01, 20414-2-C1275-02, 20414-2-C1275-03, 20414-2-C1275-04, 20414-2-C1275-05, 20414-2-C1275-06, 20414-2-C1275-07, 20414-2-C1275-08, 20414-2-C1275-09, 20414-2-C1275-11, 20414-2-C1275-12, 20414-2-C1275-13, 20414-2-C1275-15, 20414-2-C1275-16, 20414-2-C1275-17, 20414-2-C1275-18, 20414-2-C1275-19, 20414-2-C1275-20, 20414-2-C1404-01, 20414-2-C1404-02, 20414-2-C1404-03, 20414-2-C1404-04, 20414-2-C1404-06, 20414-2-C1404-07, 20414-2-C1404-08, 20414-2-C1431-08, 20414-3-C1277-01, 20414-3-C1277-02, 20414-3-C1277-03, 20414-3-C1277-04, 20414-3-C1277-05, 20414-3-C1277-06, 20414-3-C1277-07, 20414-3-C1277-08, 20414-3-C1277-09, 20414-3-C1277-10, 20414-3-C3154-01, 20414-3-C3154-02, 20414-3-C3154-03, 20414-3-C3154-04, 20414-3-C3154-05, 20414-3-C3154-06, 20414-3-C3154-08, 20414-3-C3154-09, 20414-3-C3154-10, 20414-3-C3154-11, 20414-3-C3154-12, 20414-3-C3154-13, 20414-3-C3154-14, 20414-3-C3154-15, 20414-3-C3154-16, 20414-3-C3154-17, 20414-3-C3154-18, 20414-3-C3154-19, 20414-3-C3309-01, 20414-3-C3309-03, 20414-3-C3309-05, 20414-3-C3442-01, 20414-3-C3442-02, 20414-4-C1278-01, 20414-4-C1278-02, 20414-4-C1278-03, 20414-4-C1278-04, 20414-4-C1278-05, 20414-4-C1278-06, 20414-4-C1278-07, 20414-4-C1278-08, 20414-4-C1278-09, 20414-4-C1278-10, 20414-4-C1278-11, 20414-4-C1278-12, 20414-4-C1278-13, 20414-4-C3315-01, 20414-4-C3315-04, 20414-4-C3315-05, 20414-4-C3315-06, 20414-4-C3315-07, 20414-4-C3315-08, 20414-4-C3315-09, 20414-4-C3433-01, 20414-4-C3433-02, 20414-4-C3433-03, 20414-4-C3433-04, 20414-4-C3433-05, 20414-5-C1279-10, 20414-5-C1279-14, 20414-5-C1279-15, 20414-5-C3322-01, 20414-5-C3322-02.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0227-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0228-2015 | Class II | Terminated | Voluntary: Firm initiated |