Z-0433-2015Class II

8MM,MARYLAND BIPOLAR FORCEPS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic...

Intuitive Surgical, Inc. / initiated 2014-11-03 / Terminated / root cause: labeling and UDI

Intuitive Surgical, Inc. began a recall of 8MM,MARYLAND BIPOLAR FORCEPS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments on . FDA classified it as Class II and gives the reason as "Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument". As of , the recall status on record is Terminated, and MDM tags the root cause as labeling and UDI.

Recall record

Recall number
Z-0433-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Intuitive Surgical, Inc.
Product
8MM,MARYLAND BIPOLAR FORCEPS; Intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments.
Product code
NAY System, Surgical, Computer Controlled Instrument
Reason for recall
Deviations in reprocessing steps from those stated in the reprocessing instructions can cause surface degradation of the housing and/or accelerate mechanical wear of the instrument.
Root cause tag
labeling and UDI
FDA root cause
Labeling design
Action
Urgent Medical Device Recall letters were sent to affected sites on November 3, 2014. Letters inform customers of the reason for recall, risk to health and the affected instrument. A table of all of the affected IS4000 instruments affected is attached to the letter indicating the part number and product name for each. Letters also inform customers that all instruments shipped since July 2014 are manufactured with a new material and not subject to recall. Customers are to take the following actions: 1. Ensure that all affected personnel are aware of the information. 2. Identify affected product in their possession 3. Contact ISI rep for replacement. 4. Complete and return the attached Acknowledgement From. Until replacement instruments are received, the old instruments may be used provided they do not show signs of degradation and that the reprocessing instructions are followed. Questions to 800-876-1310 Option 3 ( 6 am to 5 pm PST) or [email protected].
Quantity in commerce
5-9 units - total all devices
Distribution
US Distribution -- FL, TX, NY, NV, OR, IN, UT, and MA.
Product codes and lots
Part number: 470172-05; All 8mm da Vinci Xi (IS4000) Surgical System instruments manufactured with white colored housings.

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-0433-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-0427-2015Class IITerminatedVoluntary: Firm initiated
Z-0428-2015Class IITerminatedVoluntary: Firm initiated
Z-0429-2015Class IITerminatedVoluntary: Firm initiated
Z-0430-2015Class IITerminatedVoluntary: Firm initiated
Z-0431-2015Class IITerminatedVoluntary: Firm initiated
Z-0432-2015Class IITerminatedVoluntary: Firm initiated
Z-0433-2015Class IITerminatedVoluntary: Firm initiated
Z-0434-2015Class IITerminatedVoluntary: Firm initiated
Z-0435-2015Class IITerminatedVoluntary: Firm initiated
Z-0436-2015Class IITerminatedVoluntary: Firm initiated
Z-0437-2015Class IITerminatedVoluntary: Firm initiated
Z-0438-2015Class IITerminatedVoluntary: Firm initiated
Z-0439-2015Class IITerminatedVoluntary: Firm initiated
Z-0440-2015Class IITerminatedVoluntary: Firm initiated
Z-0441-2015Class IITerminatedVoluntary: Firm initiated
Z-0442-2015Class IITerminatedVoluntary: Firm initiated
Z-0443-2015Class IITerminatedVoluntary: Firm initiated
Z-0444-2015Class IITerminatedVoluntary: Firm initiated
Z-0445-2015Class IITerminatedVoluntary: Firm initiated
Z-0446-2015Class IITerminatedVoluntary: Firm initiated
Z-0447-2015Class IITerminatedVoluntary: Firm initiated
Z-0448-2015Class IITerminatedVoluntary: Firm initiated