ACCU-CHEK Tender I 13/60 10 pieces
Roche Diagnostics Operations, Inc. began a recall of ACCU-CHEK Tender I 13/60 10 pieces Product Usage: Usage: Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The... on . FDA classified it as Class II and gives the reason as "Roche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.
Recall record
- Recall number
- Z-0883-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Roche Diagnostics GmbH
- Product
- ACCU-CHEK Tender I 13/60 10 pieces Product Usage: Usage: Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
- Product code
- FPA Set, Administration, Intravascular
- Reason for recall
- Roche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on the ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets. If tubing detachment occurs, insulin delivery is interrupted and the pump will not alarm to notify
- Root cause tag
- design
- FDA root cause
- Device Design
- Action
- Roche sent the "Urgent Medical Device Corrections" letter dated 12/1/2014 via UPS Ground (receipt required) to the Patients, and Distributors who received the affected device. The letter included a description of the reason for recall, affected product, consignee responsibilities, and instructions for responding to the formal recall notification. No product returns were expected. For questions, contact the ACCU-CHEK Pump Support at 1-800-688-4578.
- Quantity in commerce
- Total of 13,041 boxes
- Distribution
- US Nationwide Distribution
- Product codes and lots
- Catalog: 04541405001 and Lots: 5044359, 5061929
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0883-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0884-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0885-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0886-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0887-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0888-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0889-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0890-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0891-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0892-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0893-2015 | Class II | Terminated | Voluntary: Firm initiated | ||
| Z-0894-2015 | Class II | Terminated | Voluntary: Firm initiated |