Osteobond Bone Cement Bone cement monomer is kitted with bone cement powder to create a cement mantle for...
Zimmer, Inc. began a recall of Osteobond Bone Cement Bone cement monomer is kitted with bone cement powder to create a cement mantle for orthopedic implants on . FDA classified it as Class II and gives the reason as "Samples of product from Supplier lot 14D0809 and 14D0808 showed little adhesive transfer between the Tyvek lid and cavity when opened for internal bone cement cure and pairing tests. Visually these samples do not meet...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-0900-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Zimmer GmbH
- Product
- Osteobond Bone Cement Bone cement monomer is kitted with bone cement powder to create a cement mantle for orthopedic implants.
- Product code
- LOD Bone Cement
- Reason for recall
- Samples of product from Supplier lot 14D0809 and 14D0808 showed little adhesive transfer between the Tyvek lid and cavity when opened for internal bone cement cure and pairing tests. Visually these samples do not meet the requirements of ZWI 43.109 and corresponding visual aid 55-0000-310-01.
- Root cause tag
- manufacturing process
- FDA root cause
- Employee error
- Action
- "Urgent Medical Device Recall - Lot Specific" notifications will be sent to the affected distributors, surgeons, and hospital risk managers with instructions for returning the affected product. The letters identified the affected product, reason for recall, risks, and responsibilities. Customers are to complete and return the Inventory Return Certification Form along with the affected product. Questions should be directed to the customer call at 1-800-348-2759.
- Quantity in commerce
- 40 units
- Distribution
- Distributed to MI, KS, and CA.
- Product codes and lots
- PMA #N17755, decision date 5/17/1976, reclassified 10/14/1999. Class II device; D033511, Item No. 00-1101-012-00; lot 62849791, 14D0809, Manufactured between 9/11/2014-10/6/2014; EXP date: 4/30/2017
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-0900-2015 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.