16cm Minimally Invasive Attachment. For use with Motor Systems for cutting and shaping bones, including the...
The Anspach Effort, Inc. / initiated 2014-12-10 / Terminated / root cause: manufacturing process
The Anspach Effort, Inc. began a recall of 16cm Minimally Invasive Attachment. For use with Motor Systems for cutting and shaping bones, including the spine and cranium. Model MIA16-G1 on . FDA classified it as Class II and gives the reason as "Customer complaint indicating the color bands on the MIA16-G1 were not correct". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1037-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- The Anspach Effort, Inc.
- Product
- 16cm Minimally Invasive Attachment. For use with Motor Systems for cutting and shaping bones, including the spine and cranium. Model MIA16-G1
- Product code
- HBC Motor, Drill, Electric
- Reason for recall
- Customer complaint indicating the color bands on the MIA16-G1 were not correct.
- Root cause tag
- manufacturing process
- FDA root cause
- Environmental control
- Action
- Anspach sent an "URGENT MEDICAL DEVICE RECALL" (Removal) letter dated December 10, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The firm requested the customer to 1) Immediately identify and set aside all product listed below 2) Review, complete, sign and return the attached reply form 3) Share this letter with others in your facility that need to be made aware of this recall 4) If you distribute any of the affected products to other services or facilities, please forward this letter as appropriate 5) Maintain awareness of this notice 7) Keep a copy of this notice. If you have any questions regarding this removal, please contact the Complaint Handling Unit Manager at 561-494-3673 or contact your Anspach Sales Representative.
- Quantity in commerce
- 8
- Distribution
- US Distribution to the states of: NC and CA., and Internationally to Switzerland.
- Product codes and lots
- Serial Numbers: H38309606702, H38309606704, H38309610105, H38309610104, H38309606701, H38309606703, H38309606705, H38309610101.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1037-2015 | Class II | Terminated | Voluntary: Firm initiated |
FIRST ARTICLE / WEEKLY
What cleared, what was recalled, and what changed in the standards. One edition a week for the people who make medical devices.