Z-1355-2015Class II

Various Lots of Expel Drainage Catheter with TwistLoc Hub Biliary Drainage Catheter and Biliary Drainage...

Boston Scientific Corporation / initiated 2015-02-25 / Terminated / root cause: design

Boston Scientific Corporation began a recall of Various Lots of Expel Drainage Catheter with TwistLoc Hub Biliary Drainage Catheter and Biliary Drainage Catheter Kits on . FDA classified it as Class II and gives the reason as "Complaints of device fragmentation after the catheter was implanted in the biliary system. The most serious patient risk for this issue is additional intervention for fragment retrieval using minimally invasive methods...". As of , the recall status on record is Terminated, and MDM tags the root cause as design.

Recall record

Recall number
Z-1355-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Boston Scientific Corporation
Product
Various Lots of Expel Drainage Catheter with TwistLoc Hub Biliary Drainage Catheter and Biliary Drainage Catheter Kits
Product code
FGE Stents, Drains And Dilators For The Biliary Ducts
Reason for recall
Complaints of device fragmentation after the catheter was implanted in the biliary system. The most serious patient risk for this issue is additional intervention for fragment retrieval using minimally invasive methods and, in some of the reported cases, this was performed to retrieve the device fragments.
Root cause tag
design
FDA root cause
Device Design
Action
Boston Scientific sent an Urgent Medical Device Correction - Immediate Action Required letter dated February 5, 2015. to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The letter described the problem and the product involved in the recall. Advised consignees to complete and return the "Recall Removal Reply Verification Tracking Form". Your local Sales Representative can answer any questions you may have regarding this Field Correction notice. For further questions please call (763) 494- 7971.
Quantity in commerce
289
Distribution
Worldwide Distribution - US Distribution to the states of : CA, WI, FL and OH., and to the countries of: Belgium, Czech Republic, Finland, France, Germany, Great Britain, Italy, Spain, Switzerland, Austria, Hungary, Netherlands and Portugal.
Product codes and lots
UPN # LOT # H7493933108200 17245003, 17416605, 17489192 H7493933108350 17245004, 17245005, 17370709, 17408756 H749393310835K1 17411333, 17493554 H7493933110200 17318047 H7493933110350 17275822, 17438003, 17494025, 17501572 H749393311035K1 17328808, 17403871, 17416578, 17459144 H7493933110400 17275824, 17416608 H7493933112350 17245006, 17259580, 17275819 H7493933114350 17275815, 17338207 with Expiration Dates between January 30, 2016 and May 8, 2016

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1355-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1355-2015Class IITerminatedVoluntary: Firm initiated