Vitek 2 AST-P635 REF 416 911 Gram Positive Susceptibility Card, 20 cards per container, IVD. Intended for use...
Biomerieux Inc began a recall of Vitek 2 AST-P635 REF 416 911 Gram Positive Susceptibility Card, 20 cards per container, IVD. Intended for use with the Vitek 2 Systems in clinical laboratories... on . FDA classified it as Class III and gives the reason as "The outer carton label and package insert for the recalled product incorrectly lists Streptococcus pneumoniae as an organism for intended use". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1401-2015
- Classification
- Class III
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- bioMerieux, Inc.
- Product
- Vitek 2 AST-P635 REF 416 911 Gram Positive Susceptibility Card, 20 cards per container, IVD. Intended for use with the Vitek 2 Systems in clinical laboratories as an in vitro test to determine the susceptibility of Staphylococcus spp., Enterococcus spp., and S. agalactiae.
- Product code
- LTW Susceptibility Test Cards, Antimicrobial
- Reason for recall
- The outer carton label and package insert for the recalled product incorrectly lists Streptococcus pneumoniae as an organism for intended use.
- Root cause tag
- manufacturing process
- FDA root cause
- Employee error
- Action
- Biomerieux, Incs sent an Urgent Product Correction Notice on February 25, 2015, to all affected customers. The letter identified the product, the problem, and the actions to be taken by the customer. Customers were instructed to do the following: " Please confirm this letter has been distributed and reviewed by all appropriate personnel within your organization. " For the referenced test kits (VITEK 2 ASTP635, ASTP640 or ASTP641), review the claimed organisms in the Package Insert antibiotic table to confirm which organisms can be tested. " Refrain from using the referenced test kits to determine the susceptibility of Streptococcus pneumoniae. " Reference your Laboratory Standard Operating Procedures to identify card type used for specific organisms. " Please store this letter with your bioMrieux instrument documentation. Please complete the attached Acknowledgement Form and return it to bioMrieux, Inc. Customers with questions were instructed to contact their local BioMerieux representative. For questions regarding this recall call 314-731-8526.
- Quantity in commerce
- 10409 cartons
- Distribution
- Worldwide Distribution to United Kingdom and Turkey. NO U.S. distribution.
- Product codes and lots
- lot 735352820, expiration 11AUG16; lot 735348620, expiration 30JUN16; lot 735346520, expiration 09JUN16; lot 735342320; expiration 28APR16; lot 735318020, expiration 29AUG15; lot 735315920, expiration 08AUG15; lot 735323710, expiration 25OCT15; lot 735310210, expiration 12JUN15
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1401-2015 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-1402-2015 | Class III | Terminated | Voluntary: Firm initiated | ||
| Z-1403-2015 | Class III | Terminated | Voluntary: Firm initiated |