Z-1514-2015Class II
Sony Medical Monitor LMD-1951MD 19 inch
Sony Latin America Inc / initiated 2015-03-05 / Terminated / root cause: manufacturing process
Sony Latin America began a recall of Sony Medical Monitor LMD-1951MD 19 inch on . FDA classified it as Class II and gives the reason as "Monitor has either not turned on or has lost image during clinical use". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.
Recall record
- Recall number
- Z-1514-2015
- Classification
- Class II
- Status
- Terminated
- Initiated
- Posted
- Terminated
- Recalling firm
- Sony Latin America Inc
- Product
- Sony Medical Monitor LMD-1951MD 19 inch
- Product code
- KQM Camera, Surgical And Accessories
- Reason for recall
- Monitor has either not turned on or has lost image during clinical use.
- Root cause tag
- manufacturing process
- FDA root cause
- Nonconforming Material/Component
- Action
- SOLA sent an URGENT MEDICAL DEVICE FIELD ACTION dated March 2, 2015, to all affected customers. Within that notification SOLA requests that you send the customer letter included in Attachment 1 of this notification to all customers who have purchased the affected monitors from you. The letter instructs customers who already possess an AC adapter for each of their affected monitors to only use the AC adaptor when the monitors are in use. If you have units in inventory that can be provided with an AC adapter, we will provide under separate cover kits that contain: 1) a sticker warning and 2) an adhesive seal to go over the AC outlet and 3) correction instructions document. If you have units in inventory that cannot be accompanied by an AC adapter, for each of these affected monitors, do not ship the unit until the permanent corrective action described below has been applied. Please complete the MEDICAL DEVICE RECALL RETURN RESPONSE included in Attachment 2 to the contact person identified on the form. Please contact me below if you have any questions. 305-260-4000 Hours of operation: 8am to 8pm (Monday through Friday, excluding holidays).
- Quantity in commerce
- 4,764 units
- Distribution
- Worldwide Distribution - US Distribution to the states of : FL and NC., and to the countries of : Ecuador, Costa Rica, Brazil, Nicaragua, Venezuela, Peru, Colombia, Dominican Republic, and South Korea.
- Product codes and lots
- Serial number range: 3000038-3004884, 3100035-3100058, 3100065-3100145.
Enforcement reports
One row per recalled product line| Recall number | Class | Status | Voluntary or mandated | Report date | Classified |
|---|---|---|---|---|---|
| Z-1514-2015 | Class II | Terminated | Voluntary: Firm initiated |