Z-1662-2015Class II

Water Feed Kit, Catalog#10288216,#10389714. The Immulite 2000 systems are continuous random-access...

Siemens Healthcare Diagnostics Inc. / initiated 2015-03-05 / Terminated / root cause: manufacturing process

Siemens Medical Solutions Diagnostics began a recall of Water Feed Kit, Catalog#10288216,#10389714. The Immulite 2000 systems are continuous random-access instruments that perform chemiluminescent immunoassays... on . FDA classified it as Class II and gives the reason as "The bottle assemblies were manufactured with a quality issue where in some cases the smaller diameter opening on both IMMULITE 2000 and IMMULITE 2000XPi Water Bottles and Liquid Waste Bottles is undersized and/or...". As of , the recall status on record is Terminated, and MDM tags the root cause as manufacturing process.

Recall record

Recall number
Z-1662-2015
Classification
Class II
Status
Terminated
Initiated
Posted
Terminated
Recalling firm
Siemens Healthcare Diagnostics Inc.
Product
Water Feed Kit, Catalog#10288216,#10389714. The Immulite 2000 systems are continuous random-access instruments that perform chemiluminescent immunoassays. These instruments use serum, plasma, or urine samples for in vitro diagnostic testing.
Product code
JJE Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
Reason for recall
The bottle assemblies were manufactured with a quality issue where in some cases the smaller diameter opening on both IMMULITE 2000 and IMMULITE 2000XPi Water Bottles and Liquid Waste Bottles is undersized and/or deformed, preventing the cap from closing or fastening securely to the bottle.
Root cause tag
manufacturing process
FDA root cause
Nonconforming Material/Component
Action
Siemens Healthcare Diagnostics sent an Urgent Device Correction Letter/Field Correction Effective Check Form dated 3/5/15 via FedEx to their affected customers.
Quantity in commerce
8 bottles
Distribution
Worldwide Distribution.
Product codes and lots
Water Feed Kit - Product Code/Catalog #'s 10288216 and 10389714

Enforcement reports

One row per recalled product line
FDA enforcement reports joined to recall event Z-1662-2015
Recall numberClassStatusVoluntary or mandatedReport dateClassified
Z-1658-2015Class IITerminatedVoluntary: Firm initiated
Z-1659-2015Class IITerminatedVoluntary: Firm initiated
Z-1660-2015Class IITerminatedVoluntary: Firm initiated
Z-1661-2015Class IITerminatedVoluntary: Firm initiated
Z-1662-2015Class IITerminatedVoluntary: Firm initiated
Z-1663-2015Class IITerminatedVoluntary: Firm initiated